OBJECTIVE: Patent perforators, noninvasively imaged by transthoracic color-Doppler echocardiography, may reflect adequate reperfusion in anterior myocardial infarction (MI). BACKGROUND: The Thrombolysis In Myocardial Infarction (TIMI) classification may not fully reflect adequate myocardial reperfusion in MI. METHODS: We studied 61 patients with anterior MI undergoing thrombolysis (n = 28), primary stenting (n = 20), or neither one (n = 13). High-resolution color-Doppler ultrasound was used to image the left anterior descending coronary artery (LAD) and perforators in four segments of the anterior-apical wall and to build a new recanalization score (RS). The TIMI flow was assessed by angiography. Wall motion score index (WMSI), ejection fraction (EF), end-diastolic volume index, and end-systolic volume index (ESVI) were measured by echocardiography at baseline and at three-month follow-up. Linear regression equations, considering RS or TIMI flow as independent variables, were compared among these functional recovery parameters. A multivariate linear model, predicting percent changes of WMSI, EF, or ESVI, was used to investigate the contribution of several clinical covariates along with RS and TIMI flow. RESULTS: Sensitivity, specificity, and diagnostic accuracy of color-Doppler ultrasound in detecting LAD patency were 86%, 98%, and 97%, respectively. Mean and peak flow velocities discriminated (0.004 < p < 0.008) TIMI flow but not RS. Regression equations showed that RS discriminated better than TIMI flow recovery of ventricular function (p < 0.012). The RS was the best single multivariate predictor (p < 0.0001) of percent changes in WMSI, EF, and ESVI. CONCLUSIONS: Transthoracic color-Doppler ultrasound detects an open LAD after MI. Perforators reflect adequate myocardial reperfusion and are early noninvasive markers of myocardial viability.
OBJECTIVE: Patent perforators, noninvasively imaged by transthoracic color-Doppler echocardiography, may reflect adequate reperfusion in anterior myocardial infarction (MI). BACKGROUND: The Thrombolysis In Myocardial Infarction (TIMI) classification may not fully reflect adequate myocardial reperfusion in MI. METHODS: We studied 61 patients with anterior MI undergoing thrombolysis (n = 28), primary stenting (n = 20), or neither one (n = 13). High-resolution color-Doppler ultrasound was used to image the left anterior descending coronary artery (LAD) and perforators in four segments of the anterior-apical wall and to build a new recanalization score (RS). The TIMI flow was assessed by angiography. Wall motion score index (WMSI), ejection fraction (EF), end-diastolic volume index, and end-systolic volume index (ESVI) were measured by echocardiography at baseline and at three-month follow-up. Linear regression equations, considering RS or TIMI flow as independent variables, were compared among these functional recovery parameters. A multivariate linear model, predicting percent changes of WMSI, EF, or ESVI, was used to investigate the contribution of several clinical covariates along with RS and TIMI flow. RESULTS: Sensitivity, specificity, and diagnostic accuracy of color-Doppler ultrasound in detecting LAD patency were 86%, 98%, and 97%, respectively. Mean and peak flow velocities discriminated (0.004 < p < 0.008) TIMI flow but not RS. Regression equations showed that RS discriminated better than TIMI flow recovery of ventricular function (p < 0.012). The RS was the best single multivariate predictor (p < 0.0001) of percent changes in WMSI, EF, and ESVI. CONCLUSIONS: Transthoracic color-Doppler ultrasound detects an open LAD after MI. Perforators reflect adequate myocardial reperfusion and are early noninvasive markers of myocardial viability.
Authors: Antti Saraste; Juha W Koskenvuo; Markku Saraste; Jussi Pärkkä; Jyri Toikka; Alexandru Naum; Heikki Ukkonen; Juhani Knuuti; Juhani Airaksinen; Jaakko Hartiala Journal: Heart Date: 2006-11-29 Impact factor: 5.994