Literature DB >> 12383495

Determination of nitrate and nitrite by high-performance liquid chromatography in human plasma.

Vera Jedlicková1, Zoltán Paluch, Stefan Alusík.   

Abstract

A new, accurate, fast and simple method has been implemented by which nitrite and nitrate ions, as stable forms of nitric oxide production were studied. A study of these two ions was carried out by a sensitive and accurate HPLC method with two detectors. The most important advantages of the reported method are: short time of analysis, minimal sample pre-treatment, long life of the analytical column and stable eluent solution. The photodiode array UV-Vis detector detected nitrite and nitrate ions at an absorbance of 212 nm. Much more sensitive electrochemical detection with a WE (glassy carbon) electrode was used for the detection of nitrite ions. An analytical chromatographic column was formed by a sorbent, containing strong base anion-exchange groups bound in Cl(-) form in the hydrophilic hydroxyethyl methacrylate matrix. The anions were analysed in human plasma without deproteinization using 0.02 M sodium perchlorate monohydrate as eluent solution at pH 3.9. At this pH organic substances do not affect the analysis. The retention times for nitrite and nitrate were 3.62 and 3.72 min (by electrochemical detection) and 4.44 min, respectively. The method was linear (r=0.9992, 0.9998, 0.996) within a 1-100 (nitrate), 1-20 micro mol/l (nitrite) concentration range.

Entities:  

Mesh:

Substances:

Year:  2002        PMID: 12383495     DOI: 10.1016/s1570-0232(02)00405-1

Source DB:  PubMed          Journal:  J Chromatogr B Analyt Technol Biomed Life Sci        ISSN: 1570-0232            Impact factor:   3.205


  4 in total

1.  Simultaneous Voltammetric/Amperometric Determination of Sulfide and Nitrite in Water at BDD Electrode.

Authors:  Anamaria Baciu; Magdalena Ardelean; Aniela Pop; Rodica Pode; Florica Manea
Journal:  Sensors (Basel)       Date:  2015-06-19       Impact factor: 3.576

2.  An Ultrasound Assessed Extraction Combined with Ion-Pair HPLC Method and Risk Assessment of Nitrite and Nitrate in Cured Meat.

Authors:  Babiker Yagoub Abdulkair; Amin O Elzupir; Abdulaziz S Alamer
Journal:  J Anal Methods Chem       Date:  2018-03-01       Impact factor: 2.193

3.  Au nanoparticle-loaded eggshell for electrochemical detection of nitrite.

Authors:  Qi Ding; Liping Cao; Minghuan Liu; Hetong Lin; Da-Peng Yang
Journal:  RSC Adv       Date:  2021-01-20       Impact factor: 3.361

4.  Detection of nitrite based on fluorescent carbon dots by the hydrothermal method with folic acid.

Authors:  Haitao Lin; Liyun Ding; Bingyu Zhang; Jun Huang
Journal:  R Soc Open Sci       Date:  2018-05-02       Impact factor: 2.963

  4 in total

北京卡尤迪生物科技股份有限公司 © 2022-2023.