Literature DB >> 12383336

Evaluation of the 3D BacT/ALERT automated culture system for the detection of microbial contamination of platelet concentrates.

C P McDonald1, A Rogers, M Cox, R Smith, A Roy, S Robbins, S Hartley, J A J Barbara, S Rothenberg, L Stutzman, G Widders.   

Abstract

Bacterial transmission remains the major component of morbidity and mortality associated with transfusion-transmitted infections. Platelet concentrates are the most common cause of bacterial transmission. The BacT/ALERT 3D automated blood culture system has the potential to screen platelet concentrates for the presence of bacteria. Evaluation of this system was performed by spiking day 2 apheresis platelet units with individual bacterial isolates at final concentrations of 10 and 100 colony-forming units (cfu) mL-1. Fifteen organisms were used which had been cited in platelet transmission and monitoring studies. BacT/ALERT times to detection were compared with thioglycollate broth cultures, and the performance of five types of BacT/ALERT culture bottles was evaluated. Sampling was performed immediately after the inoculation of the units, and 10 replicates were performed per organism concentration for each of the five types of BacT/ALERT bottles. The mean times for the detection of these 15 organisms by BacT/ALERT, with the exception of Propionibacterium acnes, ranged from 9.1 to 48.1 h (all 10 replicates were positive). In comparison, the time range found using thioglycollate was 12.0-32.3 h (all 10 replicates were positive). P. acnes' BacT/ALERT mean detection times ranged from 89.0 to 177.6 h compared with 75.6-86.4 h for the thioglycollate broth. BacT/ALERT, with the exception of P. acnes, which has dubious clinical significance, gave equivalent or shorter detection times when compared with the thioglycollate broth system. The BacT/ALERT system detected a range of organisms at levels of 10 and 100 cfu mL-1. This study validates the BacT/ALERT microbial detection system for screening platelets. Currently, the system is the only practically viable option available for routinely screening platelet concentrates to prevent bacterial transmission.

Entities:  

Mesh:

Substances:

Year:  2002        PMID: 12383336     DOI: 10.1046/j.1365-3148.2002.00390.x

Source DB:  PubMed          Journal:  Transfus Med        ISSN: 0958-7578            Impact factor:   2.019


  8 in total

1.  Laboratory Evaluation of the Effectiveness of Pathogen Reduction Procedures for Bacteria.

Authors:  Thomas H Müller; Thomas Montag; Axel W Seltsam
Journal:  Transfus Med Hemother       Date:  2011-07-08       Impact factor: 3.747

2.  Performance of Gram staining on blood cultures flagged negative by an automated blood culture system.

Authors:  A Peretz; N Isakovich; N Pastukh; A Koifman; T Glyatman; D Brodsky
Journal:  Eur J Clin Microbiol Infect Dis       Date:  2015-04-16       Impact factor: 3.267

Review 3.  Bacterial contamination of blood components.

Authors:  Mark E Brecher; Shauna N Hay
Journal:  Clin Microbiol Rev       Date:  2005-01       Impact factor: 26.132

4.  [Validation of an automatic test system for sterile testing of amniotic membranes].

Authors:  H Thomasen; K-P Steuhl; D Meller
Journal:  Ophthalmologe       Date:  2014-05       Impact factor: 1.059

5.  Implementation of Bacterial Detection Methods into Blood Donor Screening - Overview of Different Technologies.

Authors:  Michael Schmidt; Walid Sireis; Erhard Seifried
Journal:  Transfus Med Hemother       Date:  2011-07-07       Impact factor: 3.747

6.  Interventions Implemented to Reduce the Risk of Transmission of Bacteria by Transfusion in the English National Blood Service.

Authors:  Carl P McDonald
Journal:  Transfus Med Hemother       Date:  2011-07-15       Impact factor: 3.747

7.  The Pan Genera Detection immunoassay: a novel point-of-issue method for detection of bacterial contamination in platelet concentrates.

Authors:  Tanja Vollmer; Dennis Hinse; Knut Kleesiek; Jens Dreier
Journal:  J Clin Microbiol       Date:  2010-08-11       Impact factor: 5.948

8.  Microbiological Control of Cellular Products: The Relevance of the Cellular Matrix, Incubation Temperature, and Atmosphere for the Detection Performance of Automated Culture Systems.

Authors:  Susanne-Katharina Günther; Celina Geiss; Stefan J Kaiser; Nico T Mutters; Frank Günther
Journal:  Transfus Med Hemother       Date:  2019-10-22       Impact factor: 3.747

  8 in total

北京卡尤迪生物科技股份有限公司 © 2022-2023.