INTRODUCTION: Fluoroscopic imaging provides limited anatomic guidance for left atrial structures. The aim of this study was to determine the utility of real-time, phased-array intracardiac echocardiography during radiofrequency ablation for atrial fibrillation. METHODS AND
RESULTS: In 29 patients undergoing pulmonary vein isolation (n = 16) or linear (n = 13) left atrial radiofrequency ablation for atrial fibrillation, intracardiac phased-array echocardiography was used to visualize left atrial anatomy and the pulmonary veins, as well as ablation and mapping catheters during ablation procedures. In the 16 pulmonary vein isolation patients, the mean pulmonary vein ostial diameters measured by venography and intracardiac echocardiography were similar for all veins positions, except that left common pulmonary vein diameters were larger as measured by echocardiography (2.50 +/- 0.29 cm) than by venography (1.79 +/- 0.50 cm, P = 0.001). The ostial diameters measured by echocardiography and venography were not correlated, however (r = 0.23, P = 0.19). As directed by echocardiography, only 1 of 25 circular mapping catheters (4%) used in 16 patients was replaced due to inappropriate sizing of the pulmonary veins. Mean pulmonary vein Doppler flow velocities increased after ablation for left-sided veins but ostial diameters were unchanged. In the linear ablation patients, the entire extent of the linear electrode array could be visualized in only 3 of 52 of catheter positions (6%) in the 13 patients. A portion of the catheter could be seen in only 50% of all target catheter positions.
CONCLUSION: Phased-array intracardiac echocardiography (1) allows sizing and positioning of pulmonary vein mapping catheters, (2) provides measures of pulmonary vein ostial diameters, (3) continuously monitors pulmonary vein Doppler flow velocities, and (4) has limited use in positioning linear ablation catheters in the left atrium.

Entities:  

Mesh:

Year:  2002        PMID: 12380925     DOI: 10.1046/j.1540-8167.2002.00873.x

Source DB:  PubMed          Journal:  J Cardiovasc Electrophysiol        ISSN: 1045-3873


  10 in total

1.  Use of a non-fluoroscopic catheter navigation system for pulmonary vein isolation.

Authors:  Mark A Wood; Paul J Christman; Richard K Shepard; Kenneth A Ellenbogen
Journal:  J Interv Card Electrophysiol       Date:  2004-04       Impact factor: 1.900

Review 2.  Echocardiographic guidance of transcatheter closure of atrial septal defects: is intracardiac echocardiography better than transesophageal echocardiography?

Authors:  P Koenig; Q L Cao
Journal:  Pediatr Cardiol       Date:  2005 Mar-Apr       Impact factor: 1.655

3.  Challenges and implementation of radiation-force imaging with an intracardiac ultrasound transducer.

Authors:  Stephen J Hsu; Brian J Fahey; Douglas M Dumont; Patrick D Wolf; Gregg E Trahey
Journal:  IEEE Trans Ultrason Ferroelectr Freq Control       Date:  2007-05       Impact factor: 2.725

Review 4.  Intracardiac echocardiography in electrophysiology.

Authors:  J Kautzner; P Peichl
Journal:  Herzschrittmacherther Elektrophysiol       Date:  2007-09

Review 5.  Intracardiac echocardiography for the guidance of percutaneous procedures.

Authors:  Sawsan M Awad; Qi-Ling Cao; Ziyad M Hijazi
Journal:  Curr Cardiol Rep       Date:  2009-05       Impact factor: 2.931

6.  Vibrating interventional device detection using real-time 3-D color Doppler.

Authors:  Matthew P Fronheiser; Salim F Idriss; Patrick D Wolf; Stephen W Smith
Journal:  IEEE Trans Ultrason Ferroelectr Freq Control       Date:  2008       Impact factor: 2.725

Review 7.  Novel applications in catheter ablation.

Authors:  Sergio G Thal; Nassir F Marrouche
Journal:  J Interv Card Electrophysiol       Date:  2005-08       Impact factor: 1.900

8.  An in vitro assessment of acoustic radiation force impulse imaging for visualizing cardiac radiofrequency ablation lesions.

Authors:  Stephanie A Eyerly; Stephen J Hsu; Shruti H Agashe; Gregg E Trahey; Yang Li; Patrick D Wolf
Journal:  J Cardiovasc Electrophysiol       Date:  2009-12-15

9.  Impact of the pulmonary vein orifice area assessed using intracardiac echocardiography on the outcome of radiofrequency catheter ablation for atrial fibrillation.

Authors:  Takashi Nakashima; Masanori Kawasaki; Hiroyuki Toyoshi; Nobuhiro Takasugi; Tomoki Kubota; Hiromitsu Kanamori; Hiroaki Ushikoshi; Takuma Aoyama; Kazuhiko Nishigaki; Shinya Minatoguchi
Journal:  J Interv Card Electrophysiol       Date:  2018-02-14       Impact factor: 1.900

Review 10.  Visualization of elusive structures using intracardiac echocardiography: insights from electrophysiology.

Authors:  T Szili-Torok; E P McFadden; L J Jordaens; J R T C Roelandt
Journal:  Cardiovasc Ultrasound       Date:  2004-07-14       Impact factor: 2.062

  10 in total

北京卡尤迪生物科技股份有限公司 © 2022-2023.