Literature DB >> 12379340

Factors influencing the measurement of oestrone sulphate by dipstick particle capture immunoassay.

Keith Henderson1, Jeffrey Stewart.   

Abstract

Factors influencing the performance of a dipstick competitive particle capture immunoassay (PCI) for the steroid oestrone sulphate (OS) were investigated. Appropriate 'blocking' of the nitrocellulose dipstick membrane was necessary for the upward flow of microsphere particles. Traditional protein blocking agents including BSA, gelatin and casein were unsatisfactory while synthetic polymers and surfactants were effective in promoting microsphere movement. A simple buffer consisting of 1% aqueous NaCl containing 0.05% Tween 20 was suitable for carrying the components up the dipstick and facilitating the antibody-antigen interactions. Increasing microsphere diameters from 0.3 to 0.8 microm allowed the microsphere antibody coating concentration to be reduced which enabled lower concentrations of OS to be measured. However, upward flow rate and the maximum signal attainable was compromised as a consequence. Enlarging the dipstick membrane nominal pore size from 3 to 12 microm increased the speed of test dot development, but assay sensitivity suffered as a result in some instances. Changing the capture antigen markedly influenced the dose-response lines. No dose-response was achieved with OG-BSA as the capture antigen while OHS-BSA and OCMO-BSA as capture antigens produced dose-response lines with means +/- S.E.M. EC(50) values of 140 +/- 16 and 19 +/- 1 ng/ml, respectively.

Entities:  

Mesh:

Substances:

Year:  2002        PMID: 12379340     DOI: 10.1016/s0022-1759(02)00280-6

Source DB:  PubMed          Journal:  J Immunol Methods        ISSN: 0022-1759            Impact factor:   2.303


  3 in total

1.  Development of Lateral Flow Assay Based on Size-Controlled Gold Nanoparticles for Detection of Hepatitis B Surface Antigen.

Authors:  Dong Seok Kim; Yong Tae Kim; Seok Bok Hong; Jinwoon Kim; Nam Su Huh; Moon-Keun Lee; Seok Jae Lee; Byeong Il Kim; In Soo Kim; Yun Suk Huh; Bong Gill Choi
Journal:  Sensors (Basel)       Date:  2016-12-16       Impact factor: 3.576

Review 2.  Lab-on-a-chip pathogen sensors for food safety.

Authors:  Jeong-Yeol Yoon; Bumsang Kim
Journal:  Sensors (Basel)       Date:  2012-08-06       Impact factor: 3.576

3.  Improved LFIAs for highly sensitive detection of BNP at point-of-care.

Authors:  Yan Gong; Jie Hu; Jane Ru Choi; Minli You; Yamin Zheng; Bo Xu; Ting Wen; Feng Xu
Journal:  Int J Nanomedicine       Date:  2017-06-15
  3 in total

北京卡尤迪生物科技股份有限公司 © 2022-2023.