Literature DB >> 12375826

Performance of computed tomography for contrast agent concentration measurements with monochromatic x-ray beams: comparison of K-edge versus temporal subtraction.

H Elleaume1, A M Charvet, S Corde, F Estève, J F Le Bas.   

Abstract

We investigated the performance of monochromatic computed tomography for the quantification of contrast agent concentrations. Two subtraction methods (K-edge subtraction and temporal subtraction) were evaluated and compared theoretically and experimentally in terms of detection limit, precision and accuracy. Measurements were performed using synchrotron x-rays with Lucite phantoms (10 cm and 17.5 cm in diameter) containing iodine or gadolinium solutions ranging from 50 microg ml(-1) to 5 mg ml(-1). The experiments were carried out using monochromators developed at the European Synchrotron Radiation Facility (ESRF) medical beamline. The phantoms were imaged either above and below the contrast agent K-edge, or before and after the addition of the contrast agent. Both methods gave comparable performance for phantoms less than 10 cm in diameter. For large phantoms, equivalent to a human head, the temporal subtraction is more suitable for detecting elements such as iodine, keeping a reasonable x-ray dose delivered to the phantom. A good agreement was obtained between analytical calculations, simulations and measurements. The beam harmonic content was taken into account in the simulations. It explains the performance degradation with high contrast agent concentrations. The temporal subtraction technique has the advantage of energy tunability and is well suited for imaging elements, such as iodine or gadolinium, in highly absorbing samples. For technical reasons, the K-edge method is preferable when the imaged organ is moving since the two measurements can be performed simultaneously, which is mandatory for obtaining a good subtraction.

Entities:  

Mesh:

Substances:

Year:  2002        PMID: 12375826     DOI: 10.1088/0031-9155/47/18/307

Source DB:  PubMed          Journal:  Phys Med Biol        ISSN: 0031-9155            Impact factor:   3.609


  9 in total

1.  A dual CT-MR dendrimer contrast agent as a surrogate marker for convection-enhanced delivery of intracerebral macromolecular therapeutic agents.

Authors:  Celeste Aida S Regino; Stuart Walbridge; Marcelino Bernardo; Karen J Wong; Dennis Johnson; Russell Lonser; Edward H Oldfield; Peter L Choyke; Martin W Brechbiel
Journal:  Contrast Media Mol Imaging       Date:  2008 Jan-Feb       Impact factor: 3.161

2.  Absolute perfusion measurements and associated iodinated contrast agent time course in brain metastasis: a study for contrast-enhanced radiotherapy.

Authors:  Layal Obeid; Pierre Deman; Alexandre Tessier; Jacques Balosso; François Estève; Jean-François Adam
Journal:  J Cereb Blood Flow Metab       Date:  2014-01-22       Impact factor: 6.200

3.  Dual-energy x-ray approach for object/energy-specific attenuation coefficient correction in single-photon emission computed tomography: effects of contrast agent.

Authors:  Kheng Lim Goh; Soo Chin Liew
Journal:  J Med Imaging (Bellingham)       Date:  2021-05-31

4.  Significant dose reduction using synchrotron radiation computed tomography: first clinical case and application to high resolution CT exams.

Authors:  H Labriet; C Nemoz; M Renier; P Berkvens; T Brochard; R Cassagne; H Elleaume; F Estève; C Verry; J Balosso; J F Adam; E Brun
Journal:  Sci Rep       Date:  2018-08-21       Impact factor: 4.379

5.  K-edge subtraction imaging for coronary angiography with a compact synchrotron X-ray source.

Authors:  Stephanie Kulpe; Martin Dierolf; Eva Braig; Benedikt Günther; Klaus Achterhold; Bernhard Gleich; Julia Herzen; Ernst Rummeny; Franz Pfeiffer; Daniela Pfeiffer
Journal:  PLoS One       Date:  2018-12-10       Impact factor: 3.240

6.  Real-time X-ray imaging of mouse cerebral microvessels in vivo using a pixel temporal averaging method.

Authors:  Fucheng Yu; Feixiang Wang; Ke Li; Guohao Du; Biao Deng; Honglan Xie; Guoyuan Yang; Tiqiao Xiao
Journal:  J Synchrotron Radiat       Date:  2022-01-01       Impact factor: 2.616

7.  Synchrotron radiation-based experimental determination of the optimal energy for cell radiotoxicity enhancement following photoelectric effect on stable iodinated compounds.

Authors:  S Corde; A Joubert; J F Adam; A M Charvet; J F Le Bas; F Estève; H Elleaume; J Balosso
Journal:  Br J Cancer       Date:  2004-08-02       Impact factor: 7.640

8.  Quantitative Imaging of Regional Aerosol Deposition, Lung Ventilation and Morphology by Synchrotron Radiation CT.

Authors:  L Porra; L Dégrugilliers; L Broche; G Albu; S Strengell; H Suhonen; G H Fodor; F Peták; P Suortti; W Habre; A R A Sovijärvi; S Bayat
Journal:  Sci Rep       Date:  2018-02-23       Impact factor: 4.379

9.  K-edge Subtraction Computed Tomography with a Compact Synchrotron X-ray Source.

Authors:  Stephanie Kulpe; Martin Dierolf; Benedikt Günther; Madleen Busse; Klaus Achterhold; Bernhard Gleich; Julia Herzen; Ernst Rummeny; Franz Pfeiffer; Daniela Pfeiffer
Journal:  Sci Rep       Date:  2019-09-16       Impact factor: 4.379

  9 in total

北京卡尤迪生物科技股份有限公司 © 2022-2023.