Literature DB >> 12375706

Quality evaluation of samples obtained by spontaneous or induced sputum: comparison between two methods of processing and relationship with clinical and functional findings.

M L Bartoli1, E Bacci, S Carnevali, S Cianchetti, F L Dente, A Di Franco, D Giannini, M Taccola, B Vagaggini, P L Paggiaro.   

Abstract

The aim of the study was to assess, on a large group of spontaneous or induced sputum samples, the difference in quality between slides processed by two different methods, and the relationship between quality assessment and some clinical and functional characteristics of the examined subjects. We examined 631 sputum samples obtained from 337 subjects with proven (n = 291) or suspected bronchial asthma. Of these, 467 samples were processed using the whole-sample method (Group I), while 164 samples were processed using the plug method (Group II). Salivary contamination, cell distribution on the slide, and cell borders were evaluated, and samples were classified as inadequate, adequate, or good. Inadequate samples were equally represented in both groups, while good samples were represented more in Group II. No significant difference in most clinical and functional findings was observed between the different quality categories of both groups. A higher proportion of inadequate samples was observed in Group I samples spontaneously collected. Mild intermittent asthmatics produced a better quality of slides in comparison with other groups of asthma severity. In conclusion, sputum quality partially depends on the different methods of sputum collection and/or processing, although the percentage of inadequate samples is similar for the two methods of processing. Sputum quality is only marginally affected by clinical and functional characteristics of asthma, or by asthma severity.

Entities:  

Mesh:

Substances:

Year:  2002        PMID: 12375706     DOI: 10.1081/jas-120004907

Source DB:  PubMed          Journal:  J Asthma        ISSN: 0277-0903            Impact factor:   2.515


  3 in total

1.  Peroxisome proliferator-activated receptor-γ in induced sputum is correlated with MMP-9/TIMP-1 imbalance and formation of emphysema in COPD patients.

Authors:  Xiao-Ming Zhou; Gang Hou; Dong-Xue Gu; Qiu-Yue Wang; Li Zhao
Journal:  J Thorac Dis       Date:  2017-10       Impact factor: 2.895

2.  Long-term home noninvasive mechanical ventilation increases systemic inflammatory response in chronic obstructive pulmonary disease: a prospective observational study.

Authors:  Gregorino Paone; Vittoria Conti; Giuseppe Biondi-Zoccai; Elena De Falco; Isotta Chimenti; Mariangela Peruzzi; Corrado Mollica; Gianluca Monaco; Gilda Giannunzio; Giuseppe Brunetti; Giovanni Schmid; V Marco Ranieri; Giacomo Frati
Journal:  Mediators Inflamm       Date:  2014-05-25       Impact factor: 4.711

Review 3.  Strategies for measuring airway mucus and mucins.

Authors:  Kalina R Atanasova; Leah R Reznikov
Journal:  Respir Res       Date:  2019-11-21
  3 in total

北京卡尤迪生物科技股份有限公司 © 2022-2023.