Literature DB >> 12368795

Pitfalls associated with FasT-Fix meniscal repair.

Mark D Miller1, Alex J Kline, Joel Gonzales, William R Beach.   

Abstract

There are several devices currently available for all-inside meniscal repair. One of the newest of these devices, the FasT-Fix (Smith & Nephew, Endoscopic Division, Andover, MA), is attractive because it combines advantages of traditional inside-out meniscal repair with an all-inside technique. We chose to critically evaluate these devices in a cadaver model. FasT-Fix devices were inserted arthroscopically in 8 fresh-frozen cadaveric knees at 5 to 7 mm intervals. A total of 45 devices were placed (24 laterally, 21 medially), and the knees were subsequently dissected to determine the location of the inserted devices. Several potential pitfalls were identified during the evaluation. When using the depth penetration limiter that comes preset with the device (to a depth of 22 mm), superficial structures, including the iliotibial tract and even the skin, were at risk for penetration with the needle. The device could not effectively be inserted into the anterior meniscus or the extreme posterior horn. Other potential pitfalls seen during insertion of the FasT-Fix meniscal repair devices include suture tensioning issues (including failure of the suture during tightening), intra-articular deployment of the implants, premature deployment of both the first and second implants, difficulty in advancing the trigger for deployment of the second implant, and difficulty in placing vertical-mattress sutures. Although the FasT-Fix is already in clinical use, additional modifications would likely enhance meniscal repair using this device.

Entities:  

Mesh:

Year:  2002        PMID: 12368795     DOI: 10.1053/jars.2002.36146

Source DB:  PubMed          Journal:  Arthroscopy        ISSN: 0749-8063            Impact factor:   4.772


  14 in total

1.  Mechanical comparison of meniscal repair devices with mattress suture devices in vitro.

Authors:  Brian C Aros; Angela Pedroza; William K Vasileff; Alan S Litsky; David C Flanigan
Journal:  Knee Surg Sports Traumatol Arthrosc       Date:  2010-06-09       Impact factor: 4.342

2.  Vascular safety during arthroscopic all-inside meniscus suture.

Authors:  Akinobu Nishimura; Aki Fukuda; Ko Kato; Kohzo Fujisawa; Atsumasa Uchida; Akihiro Sudo
Journal:  Knee Surg Sports Traumatol Arthrosc       Date:  2013-11-13       Impact factor: 4.342

3.  Inside-Out Repair for Radial Meniscus Tears.

Authors:  Ayoosh Pareek; Michael P O'Malley; Bruce A Levy; Michael J Stuart; Aaron J Krych
Journal:  Arthrosc Tech       Date:  2016-07-25

4.  Inside-out meniscus repair.

Authors:  Clay G Nelson; Kevin F Bonner
Journal:  Arthrosc Tech       Date:  2013-11-01

5.  Arthroscopic all-inside meniscal repair--Does the meniscus heal? A clinical and radiological follow-up examination to verify meniscal healing using a 3-T MRI.

Authors:  Thomas Hoffelner; Herbert Resch; Rosemarie Forstner; Mayer Michael; Bernd Minnich; Mark Tauber
Journal:  Skeletal Radiol       Date:  2010-07-01       Impact factor: 2.199

6.  Determination of the safe penetration depth during all-inside meniscal repair of the posterior part of the lateral meniscus using the FasT-Fix suture repair system.

Authors:  Mohamed Mahmoud Abouheif; Hayatoshi Shibuya; Takuya Niimoto; Wirat Kongcharoensombat; Masataka Deie; Nobuo Adachi; Mitsuo Ochi
Journal:  Knee Surg Sports Traumatol Arthrosc       Date:  2011-04-06       Impact factor: 4.342

Review 7.  Treatment of meniscal tears: An evidence based approach.

Authors:  Simon C Mordecai; Nawfal Al-Hadithy; Howard E Ware; Chinmay M Gupte
Journal:  World J Orthop       Date:  2014-07-18

8.  All-inside meniscal repair.

Authors:  Kimberly A Turman; David R Diduch; Mark D Miller
Journal:  Sports Health       Date:  2009-09       Impact factor: 3.843

9.  Complications in medial meniscus suture: a cadaveric study.

Authors:  Alejandro Espejo-Baena; Pau Golano; Stephan Meschian; Jose Maria Garcia-Herrera; J M Serrano Jiménez
Journal:  Knee Surg Sports Traumatol Arthrosc       Date:  2006-06-07       Impact factor: 4.114

10.  A suture technique for easier reduction and repair of bucket-handle meniscal tears while using the all-inside devices.

Authors:  Engin Çetinkaya; Ersin Kuyucu; Murat Gül; Osman Lapçin; Kutalmış Albayrak; Sarper Gürsu
Journal:  SICOT J       Date:  2016-11-29
View more

北京卡尤迪生物科技股份有限公司 © 2022-2023.