Literature DB >> 12368734

Endoluminal versus open treatment of descending thoracic aortic aneurysms.

Sasan Najibi1, Thomas T Terramani, Victor J Weiss, M Julia Mac Donald, Peter H Lin, Douglas C Redd, Louis G Martin, Elliot L Chaikof, Alan B Lumsden.   

Abstract

PURPOSE: This report describes the authors' initial experience with the Excluder thoracic endoprosthesis (W. L. Gore and Associates, Inc, Flagstaff, Ariz) and the thoracic Talent endoprosthesis (Medtronic AVE, Sunrise, Fla) and their safety and efficacy in the primary endovascular repair of descending thoracic aortic aneurysms (TAAs). In addition, comparison with a historic nonrandomized cohort of patients that had undergone open repair of descending TAAs is reported. PATIENTS AND METHODS: Repair of TAA (mean diameter, 68 +/- 22 mm) was attempted in 19 patients with the Excluder (n = 14) and the Talent (n = 5) endoprostheses between March 1999 and January 2000. This group was compared with a historic nonrandomized cohort of 10 patients that had undergone open repair of anatomically similar descending TAA (mean diameter, 74 +/- 22 mm) between January 1996 and January 1998. The mean age in the endovascular group was 70.6 +/- 5.3 years versus 70.1 +/- 4.5 years in the historic open group. All the procedures were performed in a standard operating room with angiographic capabilities. In the historic open group, each standard tube graft repair of descending TAA was performed by one of three staff surgeons.
RESULTS: Endograft deployment was successful in 18 patients (95%). The procedure was aborted in one patient (Excluder) because of small iliac arteries and access difficulty. The average operative time was 155 +/- 62 minutes, with a mean blood loss of 325 +/- 353 mL (versus 256 +/- 102 minutes and 1205 +/- 1493 mL, respectively, in the open group). Eight patients needed the planned use of more than one component for enhanced sealing or additional length in the endovascular group. No type I endoleaks were identified on the intraoperative completion angiography. One perioperative mortality occurred in the endovascular group and the open group. In the endovascular group, other complications included retroperitoneal hematoma and external iliac artery dissection (n = 1), lymphocele (n = 1), and common femoral artery pseudoaneurysm (n = 1). In the open group, other complications included ischemic colitis (n = 1), severe renal insufficiency (n = 2), wound infection (n = 1), and stroke (n = 1). In the endovascular group, the length of stay was 6.2 +/- 3.3 days (range, 1 to 13 days), with only nine patients needing intensive care, whereas in the open group, the length of stay was 16.3 +/- 6.7 days, with all patients needing intensive care. Endoleaks, graft migrations, or ruptures were not seen on the 1-month, 6-month, and 12-month follow-up computed tomographic scans in the endovascular group. On the average, aneurysm size decreased from 68 +/- 22 mm to 58 +/- 13 mm, to 51 +/- 14 mm, and to 49 +/- 12 mm at 1, 6, and 12 months after endovascular repair, respectively. No spinal cord ischemia was seen in either group.
CONCLUSION: The endoluminal repair was effective in exclusion of descending TAAs from the systemic circulation in this selected group of patients. In this short-term follow-up, compared with the nonrandomized historic cohort of open descending TAA repair, the endovascular group had significantly shorter operating times and hospital and intensive care unit stays and lower operative blood loss. Further follow-up and continued assessment of the long-term durability of these devices in elective and emergency circumstances are warranted.

Entities:  

Mesh:

Year:  2002        PMID: 12368734

Source DB:  PubMed          Journal:  J Vasc Surg        ISSN: 0741-5214            Impact factor:   4.268


  15 in total

Review 1.  TEVAR: Endovascular Repair of the Thoracic Aorta.

Authors:  David A Nation; Grace J Wang
Journal:  Semin Intervent Radiol       Date:  2015-09       Impact factor: 1.513

2.  Practice patterns for thoracic aneurysms in the stent graft era: health care system implications.

Authors:  Karen L Walker; Jonathan J Shuster; Tomas D Martin; Philip J Hess; Charles T Klodell; Robert J Feezor; Adam W Beck; Thomas M Beaver
Journal:  Ann Thorac Surg       Date:  2010-12       Impact factor: 4.330

Review 3.  Complications of endovascular aneurysm repair of the thoracic and abdominal aorta: evaluation and management.

Authors:  Dania Daye; T Gregory Walker
Journal:  Cardiovasc Diagn Ther       Date:  2018-04

4.  Endovascular repair of the thoracic aorta.

Authors:  Grace J Wang; Ronald M Fairman
Journal:  Semin Intervent Radiol       Date:  2009-03       Impact factor: 1.513

5.  Hybrid procedures combining conventional and thoracic endovascular aortic repair for thoracic aortic aneurysms.

Authors:  Yukio Obitsu; Nobusato Koizumi; Satoshi Takahashi; Yasunori Iida; Naozumi Saiki; Yoshiko Watanabe; Satoshi Kawaguchi; Hiroshi Shigematsu
Journal:  Surg Today       Date:  2011-07-12       Impact factor: 2.549

Review 6.  Spinal cord injury as a complication of thoracic endovascular aneurysm repair.

Authors:  Taijiro Sueda; Shinya Takahashi
Journal:  Surg Today       Date:  2017-09-18       Impact factor: 2.549

7.  Initial experience in the treatment of thoracic aortic aneurysmal disease with a thoracic aortic endograft at Baylor University Medical Center.

Authors:  Jeffrey Apple; Karen L McQuade; Baron L Hamman; Robert F Hebeler; William P Shutze; Dennis R Gable
Journal:  Proc (Bayl Univ Med Cent)       Date:  2008-04

8.  Endovascular repair of descending thoracic aortic aneurysm: an evidence-based analysis.

Authors: 
Journal:  Ont Health Technol Assess Ser       Date:  2005-11-01

9.  Stent graft treatment for thoracic and thoracoabdominal aortic disease using a unibody Z-stent that adapts to flexure.

Authors:  Masahiro Aiba; Toshi Hashimoto; Hiroyuki Tanaka; Yoshiharu Okada; Makoto Yamada; Tadanori Kawada
Journal:  J Artif Organs       Date:  2007-09-20       Impact factor: 1.731

10.  The combined use of multilayer flow modulator stent and conventional stent grafts in complex thoracoabdominal aortic aneurysms and Type 3 dissections accompanying aneurysms.

Authors:  Cengiz Ovalı; Mustafa Behçet Sevin
Journal:  Turk Gogus Kalp Damar Cerrahisi Derg       Date:  2018-04-30       Impact factor: 0.332

View more

北京卡尤迪生物科技股份有限公司 © 2022-2023.