Optimization of multiple spin-echo sequences for 3D polymer gel dosimetry.

Y De Deene1, C Baldock.   

Abstract

The overall performance of polymer gel dosimeters for three-dimensional radiation dosimetry is determined by the temporal and spatial stability of the gels, dose sensitivity and image quality with respect to both systematic and stochastic deviations. The dose resolution (D(p)delta) is determined by the dose sensitivity and the signal-to-noise ratio (SNR) in the dose images. The dose sensitivity can be altered by changing the chemical composition of the polymer gel. The SNR is determined by the scanner and the imaging sequence. In the dose verification of conformal radiotherapy treatments the chosen number of slices may reach a number of 10-20. For these experiments, to obtain a sufficient SNR within a reasonable measurement time using a certain MR scanner, the imaging sequence should be optimized. A few other studies have emphasized the importance of optimizing the imaging sequence with respect to dose resolution (D(p)delta) or SNR but do not give quantitative values for the optimal sequence parameters for scanning a polymer gel dosimeter in three dimensions. In this paper, it is proved that a multiple spin-echo sequence is preferable to a single spin-echo sequence. It is also shown that when using a multiple spin-echo sequence it is not the inter-echo time that should be optimized but the number of echoes. An algebraical expression is derived for the dose resolution in terms of sequence parameters. A mathematical formalism and look-up tables are provided that can be used to optimize both a single and a slice-selective multiple spin-echo sequence to acquire a set of dose images at various locations. The use of the optimization protocol is illustrated by some examples. The optimization protocol enables the user to derive the optimal sequence parameters to acquire a set of dose maps obtained by quantitative T2 imaging for each polymer gel dosimeter within the shortest time possible.

Entities:  

Mesh:

Substances:

Year:  2002        PMID: 12361214     DOI: 10.1088/0031-9155/47/17/306

Source DB:  PubMed          Journal:  Phys Med Biol        ISSN: 0031-9155            Impact factor:   3.609


  9 in total

1.  Improved MAGIC gel for higher sensitivity and elemental tissue equivalent 3D dosimetry.

Authors:  Xuping Zhu; Timothy G Reese; Elizabeth M Crowley; Georges El Fakhri
Journal:  Med Phys       Date:  2010-01       Impact factor: 4.071

2.  A variable echo-number method for estimating R2 in MRI-based polymer gel dosimetry.

Authors:  Yoichi Watanabe; Hitoshi Kubo
Journal:  Med Phys       Date:  2011-02       Impact factor: 4.071

Review 3.  Polymer gel dosimetry.

Authors:  C Baldock; Y De Deene; S Doran; G Ibbott; A Jirasek; M Lepage; K B McAuley; M Oldham; L J Schreiner
Journal:  Phys Med Biol       Date:  2010-02-11       Impact factor: 3.609

4.  Adaptation of radiation field analyser (RFA) as optical CT scanner for gel dosimetry.

Authors:  S Brindha; Vinoth Kumar; S Vasanth; B Ravindran Paul
Journal:  J Med Phys       Date:  2006-01

5.  Small field dose delivery evaluations using cone beam optical computed tomography-based polymer gel dosimetry.

Authors:  Timothy Olding; Oliver Holmes; Paul Dejean; Kim B McAuley; Ken Nkongchu; Giles Santyr; L John Schreiner
Journal:  J Med Phys       Date:  2011-01

6.  Uncertainty Analysis in MRI-based Polymer Gel Dosimetry.

Authors:  M Keshtkar; M H Zahmatkesh; A R Montazerabadi
Journal:  J Biomed Phys Eng       Date:  2017-09-01

7.  Application of high field magnetic resonance microimaging in polymer gel dosimetry.

Authors:  Agnieszka Skorupa; Aleksandra Woźnica; Mateusz Ciszek; Michał Staniszewski; Marek Kijonka; Marek Kozicki; Bożena Woźniak; Andrzej Orlef; Andrzej Polański; Łukasz Boguszewicz; Maria Sokół
Journal:  Med Phys       Date:  2020-05-15       Impact factor: 4.071

Review 8.  Radiation Dosimetry by Use of Radiosensitive Hydrogels and Polymers: Mechanisms, State-of-the-Art and Perspective from 3D to 4D.

Authors:  Yves De Deene
Journal:  Gels       Date:  2022-09-19

9.  Indigenously developed multipurpose acrylic head phantom for verification of IMRT using film and gel dosimetry.

Authors:  N Gopishankar; S Vivekanandhan; G K Rath; M A Laviraj; S Senthilkumaran; S S Kale; S Thulkar; R K Bisht; V Subramani
Journal:  J Appl Clin Med Phys       Date:  2013-03-04       Impact factor: 2.102

  9 in total

北京卡尤迪生物科技股份有限公司 © 2022-2023.