Literature DB >> 12361169

First results with wavefront-guided photorefractive keratectomy for hyperopia.

Zoltán Z Nagy1, Ilona Palágyi-Deak, Andrea Kovács, Edit Kelemen, Werner Förster.   

Abstract

PURPOSE: To compare the results of traditional laser photoablation and wavefront-supported customized ablation (WASCA) in hyperopic photorefractive keratectomy (H-PRK).
METHODS: This was a prospective study, comparing two treatment groups, each comprising 40 eyes of 20 patients. Wavefront aberrations were examined using a Shack-Hartmann aberrometer. Preoperative refraction was similar in the two groups; in the traditional H-PRK group (Group 1) it was +3.10 +/- 0.85 D, and in the WASCA-guided group (Group 2) it was +2.90 +/- 0.80 D. H-PRK was performed with the Asclepion-Meditec MEL 70 flying-spot excimer laser. The follow-up time was 6 months.
RESULTS: In Group 1, mean postoperative refraction was +0.14 +/- 0.24 D, and in Group 2, -0.10 +/- 0.25 D; mean uncorrected visual acuity was 0.92 +/- 0.16 in Group 1 and 0.95 +/- 0.18 in Group 2. Mean best spectacle-corrected visual acuity was 0.96 +/- 0.04 in Group 1 and 1.06 +/- 0.13 in Group 2. In Group 1, 67.5% (27 of 40 eyes), and in Group 2, 85% (34 of 40 eyes) were within +/-0.50 D of target refraction. Regarding change of spectacle-corrected visual acuity in Group 1, 5% (2 of 40 eyes), and in Group 2, 20% (8 of 40 eyes) gained one Snellen line compared to the preoperative; in Group 1, 10% (4 of 40 eyes), and in Group 2, 12.5% (5 of 40 eyes) lost two Snellen lines. In Group 2, the root mean square value for the higher order aberration increased from the initial 0.134 to 0.257 microm at 6 months after surgery.
CONCLUSIONS: WASCA-guided hyperopic-PRK treatment was found to be safe and predictable. The results were better than those achieved with traditional PRK performed using the same flying-spot type excimer laser.

Entities:  

Mesh:

Year:  2002        PMID: 12361169     DOI: 10.3928/1081-597X-20020901-24

Source DB:  PubMed          Journal:  J Refract Surg        ISSN: 1081-597X            Impact factor:   3.573


  4 in total

Review 1.  [Wavefront analysis and adaptive optics].

Authors:  J D Stevens; W Sekundo
Journal:  Ophthalmologe       Date:  2003-06-17       Impact factor: 1.059

Review 2.  [Current state of wavefront guided corneal surgery to correct refraction disorders].

Authors:  T Kohnen; J Bühren
Journal:  Ophthalmologe       Date:  2004-06       Impact factor: 1.059

3.  Wavefront excimer laser refractive surgery for adults with refractive errors.

Authors:  Shi-Ming Li; Meng-Tian Kang; Ning-Li Wang; Samuel A Abariga
Journal:  Cochrane Database Syst Rev       Date:  2020-12-18

4.  Variability of wavefront aberration measurements in small pupil sizes using a clinical Shack-Hartmann aberrometer.

Authors:  Harilaos S Ginis; Sotiris Plainis; Aristophanis Pallikaris
Journal:  BMC Ophthalmol       Date:  2004-02-11       Impact factor: 2.209

  4 in total