Literature DB >> 12360387

Feasibility of pulmonary artery pressure measurements in infants through aorto-pulmonary shunts using a micromanometer pressure wire.

A D Everett1, G P Matherne.   

Abstract

Assessment of pulmonary artery pressure is an essential element in the evaluation of children palliated with surgical aorto-pulmonary shunts prior to definitive surgical repair. We report the ease of use and accuracy of a 0.014 inch micromanometer pressure wire for the measurement of pulmonary artery pressures in children with aorto-pulmonary artery shunts. The study population consisted of 11 infants and children with either a 3.5 mm modified Blalock-Taussig shunt from the subclavian artery to the branch pulmonary artery after stage 1 Norwood repair for hypoplastic left heart syndrome or palliative staged repair for tetralogy of Fallot, or a central shunt for pulmonary atresia or double outlet right ventricle. The unique features of the micromanometer pressure wire allowed rapid access and accurate measurement of pulmonary pressures in all patients studied. We conclude that the micromanometer pressure wire is a unique and accurate alternative device for rapid and safe determinations of pulmonary artery pressures in children with aorto-pulmonary artery shunts.

Entities:  

Mesh:

Substances:

Year:  2002        PMID: 12360387     DOI: 10.1007/s00246-002-0315-0

Source DB:  PubMed          Journal:  Pediatr Cardiol        ISSN: 0172-0643            Impact factor:   1.655


  5 in total

1.  Fractional flow reserve to determine the appropriateness of angioplasty in moderate coronary stenosis: a randomized trial.

Authors:  G J Bech; B De Bruyne; N H Pijls; E D de Muinck; J C Hoorntje; J Escaned; P R Stella; E Boersma; J Bartunek; J J Koolen; W Wijns
Journal:  Circulation       Date:  2001-06-19       Impact factor: 29.690

2.  Reliability of fractional flow reserve measurements in patients with associated microvascular dysfunction: importance of flow on translesional pressure gradient.

Authors:  M J Claeys; J M Bosmans; J Hendrix; C J Vrints
Journal:  Catheter Cardiovasc Interv       Date:  2001-12       Impact factor: 2.692

3.  Obstruction of systemic pulmonary arterial shunts by diagnostic cardiac catheters.

Authors:  T R Lloyd; R L Donnerstein; F Shirazi
Journal:  Am J Cardiol       Date:  1990-10-01       Impact factor: 2.778

4.  Miniaturized pressure-guide-wire: evaluation in vitro and in isolated hearts.

Authors:  G Görge; R Erbel; S Niessing; F Schön; P Kearney; J Meyer
Journal:  Cathet Cardiovasc Diagn       Date:  1993-12

5.  Abnormal epicardial coronary resistance in patients with diffuse atherosclerosis but "Normal" coronary angiography.

Authors:  B De Bruyne; F Hersbach; N H Pijls; J Bartunek; J W Bech; G R Heyndrickx; K L Gould; W Wijns
Journal:  Circulation       Date:  2001-11-13       Impact factor: 29.690

  5 in total