Literature DB >> 12358959

The effect of introducer gauge, design and bevel direction on the deflection of spinal needles.

W-S Ahn1, J-H Bahk, Y-J Lim, Y-C Kim.   

Abstract

This study was performed to determine how the use of an introducer affects the extent to which a needle deflects during a spinal or combined spinal-epidural injection. A polystyrene block was used to simulate the paraspinal area of the back. A line was drawn perpendicular to the edge of the block to use as a guide and to measure the deflection. The use of an introducer needle decreased the deflection in all the bevelled needles (p < 0.001). Depending on the direction of both the bevels, the deflection decreased as the introducer bevel was changed from the same direction, to right-angles to bevel direction and then to a direction opposite to that of the spinal needle (p < 0.05). Deflection was decreased when a thick introducer was used (p < 0.001). The use of an introducer increased the deflection of the pencil-point needle only in the deflection direction of the introducer (p < 0.001). The 18-gauge Tuohy needle with a "backhole" deflected more than the corresponding needle without a backhole (p < 0.001), and the spinal needle inserted through the Tuohy needle with a backhole deflected more (p = 0.002). Besides the tip type and gauge, the deflection of a spinal needle depends upon the use of introducer, its gauge and bevel direction. The deflection of a Tuohy needle depends upon its design, gauge and the presence of a backhole.

Entities:  

Mesh:

Year:  2002        PMID: 12358959     DOI: 10.1046/j.1365-2044.2002.02657.x

Source DB:  PubMed          Journal:  Anaesthesia        ISSN: 0003-2409            Impact factor:   6.955


  6 in total

1.  The effect of preeclampsia on the skin to subarachnoid distance in spinal anesthesia.

Authors:  B Basaran; A Basaran; B Kozanhan; S Ozmen; M Basaran
Journal:  J Anesth       Date:  2014-11-07       Impact factor: 2.078

2.  All epidural needle bevels are not the same.

Authors:  Amber C Benhardt; Bhavani Shankar Kodali
Journal:  Indian J Anaesth       Date:  2021-04-15

3.  Characterization of pre-curved needles for steering in tissue.

Authors:  Thomas R Wedlick; Allison M Okamura
Journal:  Conf Proc IEEE Eng Med Biol Soc       Date:  2009

4.  [Intended and actual paths of epidural needles. Investigations with a test tissue model].

Authors:  H Baumann; J Biscoping
Journal:  Anaesthesist       Date:  2007-08       Impact factor: 1.041

5.  Comparison of Spinal Needle Deflection in a Ballistic Gel Model.

Authors:  Ethan Rand; George Christolias; Christopher Visco; Jaspal R Singh
Journal:  Anesth Pain Med       Date:  2016-05-30

6.  Prospective randomized comparison of cerebrospinal fluid aspiration and conventional popping methods using 27-gauge spinal needles in patients undergoing spinal anaesthesia.

Authors:  J U Han; B G Kim; C Yang; W H Choi; J Jeong; K J Lee; H Kim
Journal:  BMC Anesthesiol       Date:  2020-01-30       Impact factor: 2.217

  6 in total

北京卡尤迪生物科技股份有限公司 © 2022-2023.