Literature DB >> 12358168

The immediate reproducibility of T wave alternans during bicycle exercise.

Daniel M Bloomfield1, Brooke S Ritvo, Michael K Parides, Michael H Kim.   

Abstract

A number of recent studies have demonstrated that the microvolt level T wave alternans measured during bicycle exercise can identify patients at high risk for developing malignant ventricular arrhythmias. However, little is known about the reproducibility of T wave alternans measured during bicycle exercise. The purpose of this study was to prospectively evaluate the immediate reproducibility of T wave alternans measured during bicycle exercise testing. Thirty-five patients with congestive heart failure underwent two sequential bicycle exercise tests with the measurement of T wave alternans. The T wave alternans tests were randomly sorted and then classified by two readers who were blinded to the patient and the sequence of the two tests. Tests were classified as determinate (positive or negative) or indeterminate according to previously published criteria. Of the 22 patients that had two determinate T wave alternans tests, 18 (82%) of 22 patients had concordant test results (kappa 0.58). Of the four patients who had discordant test results on the two tests, three patients had one test that was borderline and difficult to interpret. One patient had two sequential tests that were clearly different. Of the ten patients whose initial test was indeterminate, five became determinate on the second test. T wave alternans measured during bicycle exercise has an acceptable reproducibility when measurements are madefrom two sequential exercise tests performed within a short period. This data suggests that the measurement of T wave alternans during exercise is reliable. Repeating the exercise test with a second measure of T wave alternans during the same session can significantly reduce the proportion of patients with indeterminate test results.

Entities:  

Mesh:

Year:  2002        PMID: 12358168     DOI: 10.1046/j.1460-9592.2002.01185.x

Source DB:  PubMed          Journal:  Pacing Clin Electrophysiol        ISSN: 0147-8389            Impact factor:   1.976


  7 in total

1.  Temporal variations in microvolt T-wave alternans testing after acute myocardial infarction.

Authors:  Mário Martins Oliveira; António Fiarresga; Nuno Pelicano; Nogueira da Silva; Ana Teresa Timóteo; Isabel Carlos; Sofia Silva; Jorge Quininha
Journal:  Ann Noninvasive Electrocardiol       Date:  2007-04       Impact factor: 1.468

Review 2.  T-wave alternans: reviewing the clinical performance, understanding limitations, characterizing methodologies.

Authors:  Euler de Vilhena Garcia
Journal:  Ann Noninvasive Electrocardiol       Date:  2008-10       Impact factor: 1.468

3.  Microvolt T-wave alternans in patients undergoing elective coronary artery bypass grafting: a pilot study.

Authors:  G Khoueiry; M Abdallah; M Shariff; M Kowalski; J Lafferty
Journal:  Heart Lung Vessel       Date:  2015

4.  Electromuscular incapacitating devices discharge and risk of severe bradycardia.

Authors:  Stepan Havranek; Petr Neuzil; Ales Linhart
Journal:  Am J Forensic Med Pathol       Date:  2015-06       Impact factor: 0.921

5.  Microvolt T-wave alternans profiles in patients with pulmonary arterial hypertension compared to patients with left ventricular systolic dysfunction and a group of healthy volunteers.

Authors:  Ludmila Danilowicz-Szymanowicz; Ewa Lewicka; Alicja Dabrowska-Kugacka; Agnieszka Niemirycz-Makurat; Joanna Kwiatkowska; Zuzanna Lewicka-Potocka; Katarzyna Rozwadowska; Emilia Stepnowska; Grzegorz Raczak
Journal:  Anatol J Cardiol       Date:  2016-04-07       Impact factor: 1.596

6.  The need for studies to evaluate the reproducibility of the T-wave alternans (TWA), and the rationale for a correction index of the TWA.

Authors:  John E Madias
Journal:  Indian Pacing Electrophysiol J       Date:  2007-08-01

7.  Usefulness of microvolt T-wave alternans testing in the assessment of all-cause mortality and life-threatening ventricular arrhythmia risk in patients with left ventricular dysfunction.

Authors:  Ludmiła Daniłowicz-Szymanowicz; Małgorzata Szwoch; Alicja Dąbrowska-Kugacka; Maria Dudziak; Dariusz Kozłowski; Grzegorz Raczak
Journal:  Arch Med Sci       Date:  2014-01-10       Impact factor: 3.318

  7 in total