Displacement of a cemented polished tapered stem during closed reduction of a dislocated total hip arthroplasty--a case report.

Matias Petracchi1, Alejandro González Della Valle, Martin Buttaro, Francisco Piccaluga.   

Abstract

Entities:  

Mesh:

Year:  2002        PMID: 12358125     DOI: 10.1080/00016470216309

Source DB:  PubMed          Journal:  Acta Orthop Scand        ISSN: 0001-6470


× No keyword cloud information.
  4 in total

1.  Displacement of a cemented femoral implant. A complication of manipulation of a dislocated total hip replacement.

Authors:  Stephen Ng Man Sun; Elizabeth Gillott; Neil Davies; John Skinner
Journal:  BMJ Case Rep       Date:  2012-12-03

2.  Femoral stem displacement in a patient suffering recurrent dislocations after hip hemiarthroplasty: case report.

Authors:  Panagiotis Tsagozis; Magnus Henriksson; Ioannis Ioannidis
Journal:  Open Orthop J       Date:  2011-12-30

3.  Dissociation of Cemented Dual Mobility Socket from the Acetabulum in A Case of Recurrent Total Hip Arthroplasty Instability -A Novel Complication.

Authors:  Rakesh John; Anuj Jain; Shekhar Agarwal; Simon Thomas; Sunny Agarwal
Journal:  J Orthop Case Rep       Date:  2018 Nov-Dec

4.  Dislodgement of a cemented exeter femoral stem during closed manipulative reduction of a dislocated total hip replacement.

Authors:  Aysha Rajeev; Abdalla Mohamed; Mazharuddin Shaikh; Paul Banaszkiewicz
Journal:  Int J Surg Case Rep       Date:  2016-03-18