Literature DB >> 12355303

Clinical evaluation of meniscus repair with a bioabsorbable arrow: a 2- to 3-year follow-up study.

A Ellermann1, R Siebold, J U Buelow, C Sobau.   

Abstract

In a clinical study with the bioabsorbable Bionx Meniscus Arrow we prospectively evaluated 113 consecutive patients (113 menisci) after all-inside meniscus repair. Repairs were performed in either the medial (80.5%) or lateral (19.5%) posterior horn in the red-red or red-white meniscal zone; 66% of patients underwent concomitant ACL reconstruction. Assessment was based on history, clinical examination, and Lysholm [37] and Cincinnati Knee Scores. After a mean follow-up was 33 months (range 24-43; n=105) 21 (20%) patients showed signs and symptoms consistent with a meniscus tear (16 medial, 5 lateral) and underwent partial meniscectomy. In 11 (52%) of the revised patients concomitant ACL reconstruction was performed; 4 (19%) of revised patients were older than 35 years. In the nonrevised the average Lysholm Score was 92.5 and the average Cincinnati Score 90.4. Two patients showed a distinct femoral cartilage damage. Patient's age did not significantly affect the revision rate. Meniscus repair with the bioabsorbable arrow leads to clinical results comparable to those of traditional suture techniques. When stabilized, patients with concomitant ACL reconstruction showed comparable results to patients without ACL rupture. The simple and time saving all-inside insertion obviates the need for additional incisions and avoids knot tying. A proper tear selection and arrow positioning is necessary and should avoid cartilage damage.

Entities:  

Mesh:

Substances:

Year:  2002        PMID: 12355303     DOI: 10.1007/s00167-002-0301-3

Source DB:  PubMed          Journal:  Knee Surg Sports Traumatol Arthrosc        ISSN: 0942-2056            Impact factor:   4.342


  11 in total

Review 1.  Migration of a broken meniscal arrow: a case report and review of the literature.

Authors:  A Y Bonshahi; P Hopgood; G J Shepard
Journal:  Knee Surg Sports Traumatol Arthrosc       Date:  2003-09-26       Impact factor: 4.342

2.  A new rigid biodegradable anchor for meniscus refixation: biomechanical evaluation.

Authors:  Thore Zantop; Anne Kathleen Eggers; Volker Musahl; Andre Weimann; Joachim Hassenpflug; Wolf Petersen
Journal:  Knee Surg Sports Traumatol Arthrosc       Date:  2003-12-19       Impact factor: 4.342

3.  Chondral injury due to migration of a Mitek RapidLoc meniscal repair implant after successful meniscal repair: a case report.

Authors:  J Gliatis; A Kouzelis; A Panagopoulos; E Lambiris
Journal:  Knee Surg Sports Traumatol Arthrosc       Date:  2004-10-20       Impact factor: 4.342

4.  Mid-term clinical results of medial meniscus repair with the meniscus arrow in the unstable knee.

Authors:  Nikolaos Koukoulias; Stergios Papastergiou; Konstantinos Kazakos; Georgios Poulios; Konstantinos Parisis
Journal:  Knee Surg Sports Traumatol Arthrosc       Date:  2006-09-12       Impact factor: 4.342

Review 5.  Meta-analysis on biomechanical properties of meniscus repairs: are devices better than sutures?

Authors:  Daniel M Buckland; Patrick Sadoghi; Matthias D Wimmer; Patrick Vavken; Geert I Pagenstert; Victor Valderrabano; Claudio Rosso
Journal:  Knee Surg Sports Traumatol Arthrosc       Date:  2014-05-20       Impact factor: 4.342

6.  It is safe and effective to use all inside meniscal repair devices for posteromedial meniscal 'ramp' lesions.

Authors:  Giles Heilpern; Jo Stephen; Simon Ball; Andrew Amis; Andy Williams
Journal:  Knee Surg Sports Traumatol Arthrosc       Date:  2018-05-12       Impact factor: 4.342

7.  [Surgical treatment of knee joint osteoarthritis in the middle-aged patient].

Authors:  Martin Pietsch; Siegfried Hofmann
Journal:  Wien Med Wochenschr       Date:  2007-01

8.  MRI of menisci repaired with bioabsorbable arrows.

Authors:  Antti O T Mustonen; Laura Tielinen; Jan Lindahl; Eero Hirvensalo; Martti Kiuru; Seppo K Koskinen
Journal:  Skeletal Radiol       Date:  2006-03-18       Impact factor: 2.199

9.  Retears of postoperative knee meniscus: findings on magnetic resonance imaging (MRI) and magnetic resonance arthrography (MRA) by using low and high field magnets.

Authors:  Paolo Cardello; Carlo Gigli; Alessandra Ricci; Leonardo Chiatti; Nicola Voglino; Enrico Pofi
Journal:  Skeletal Radiol       Date:  2008-10-10       Impact factor: 2.199

10.  All-inside meniscal repair.

Authors:  Kimberly A Turman; David R Diduch; Mark D Miller
Journal:  Sports Health       Date:  2009-09       Impact factor: 3.843

View more