Literature DB >> 12354992

Single-vessel coronary artery stenosis: myocardial perfusion imaging with Gadomer-17 first-pass MR imaging in a swine model of comparison with gadopentetate dimeglumine.

Bernhard L Gerber1, David A Bluemke, Bennett B Chin, Raymond C Boston, Alan W Heldman, João A C Lima, Dara L Kraitchman.   

Abstract

PURPOSE: To evaluate the ability of Gadomer-17 to depict perfusion defects in a closed-chest swine model of single-vessel coronary artery disease.
MATERIALS AND METHODS: Twelve pigs underwent closed-chest placement of a flow reducer for 70%-90% luminal stenosis in the proximal left anterior coronary artery. Magnetic resonance (MR) perfusion imaging with Gadomer-17 and gadopentetate dimeglumine, microsphere blood flow (MBF) testing, and technetium 99m ((99m)Tc) 2 methoxyisobutylisonitrile (MIBI) single photon emission computed tomography (SPECT) were performed during dipyridamole vasodilation. Comparisons of percentage signal intensity (SI) increase (PSIC) in remote and ischemic myocardium were made with repeated measurements analysis of variance after injection of both tracers.
RESULTS: Perfusion defects and reduced PSIC in the anterior ischemic versus the inferior remote myocardium could be identified after injection of both Gadomer-17 (PSIC, 66% +/- 30 [mean +/- SD] vs 100% +/- 32, respectively; P <.001) and gadopentetate dimeglumine (PSIC, 49% +/- 31 vs 81% +/- 43, respectively; P <.005). The size of perfusion defect depicted with both tracers was highly correlated with defect size at (99m)Tc MIBI SPECT (r = 0.69, P <.05 for Gadomer-17 and r = 0.60, P =.05 for gadopentetate dimeglumine) and with areas of reduced MBF (r = 0.70, P <.05 for Gadomer-17 and r = 0.80, P <.05 for gadopentetate dimeglumine). PSIC also correlated with MBF (r = 0.89, P <.001 for Gadomer-17 and r = 0.75, P <.001 for gadopentetate dimeglumine). Gadomer-17 allowed differentiation of ischemic from nonischemic myocardium, as demonstrated by reduced PSIC (PSIC, 48% +/- 38 vs 72% +/- 31, respectively; P <.001) until 20 minutes after contrast material injection. In contrast, differentiation of ischemic from nonischemic myocardium was possible only until 55 seconds after injection of gadopentetate dimeglumine (PSIC, 36% +/- 24 vs 56% +/- 27, respectively; P <.005) but not at any time point thereafter.
CONCLUSION: With the study conditions, Gadomer-17 provided more prolonged differentiation of ischemic from remote myocardium than that with gadopentetate dimeglumine.

Entities:  

Mesh:

Substances:

Year:  2002        PMID: 12354992     DOI: 10.1148/radiol.2251011377

Source DB:  PubMed          Journal:  Radiology        ISSN: 0033-8419            Impact factor:   11.105


  7 in total

Review 1.  Magnetic resonance approaches and recent advances in myocardial perfusion imaging.

Authors:  Daniel C Lee; Francis J Klocke
Journal:  Curr Cardiol Rep       Date:  2006-02       Impact factor: 2.931

Review 2.  Magnetic resonance cardiac perfusion imaging-a clinical perspective.

Authors:  Peter Hunold; Thomas Schlosser; Jörg Barkhausen
Journal:  Eur Radiol       Date:  2006-05-03       Impact factor: 5.315

3.  Myocardial perfusion reserve index during adenosine stress magnetic resonance for the detection of coronary artery disease - ready for prime time?

Authors:  Grigorios Korosoglou; Hugo A Katus
Journal:  J Thorac Dis       Date:  2013-06       Impact factor: 2.895

4.  Computed tomography angiography and perfusion to assess coronary artery stenosis causing perfusion defects by single photon emission computed tomography: the CORE320 study.

Authors:  Carlos E Rochitte; Richard T George; Marcus Y Chen; Armin Arbab-Zadeh; Marc Dewey; Julie M Miller; Hiroyuki Niinuma; Kunihiro Yoshioka; Kakuya Kitagawa; Shiro Nakamori; Roger Laham; Andrea L Vavere; Rodrigo J Cerci; Vishal C Mehra; Cesar Nomura; Klaus F Kofoed; Masahiro Jinzaki; Sachio Kuribayashi; Albert de Roos; Michael Laule; Swee Yaw Tan; John Hoe; Narinder Paul; Frank J Rybicki; Jeffery A Brinker; Andrew E Arai; Christopher Cox; Melvin E Clouse; Marcelo F Di Carli; Joao A C Lima
Journal:  Eur Heart J       Date:  2013-11-19       Impact factor: 29.983

5.  Detection of moderate regional ischemia in pig hearts in vivo by near-infrared and thermal imaging: effects of dipyridamole.

Authors:  Valery V Kupriyanov; Darren M Manley; Bo Xiang
Journal:  Int J Cardiovasc Imaging       Date:  2007-04-13       Impact factor: 2.357

6.  An isolated perfused pig heart model for the development, validation and translation of novel cardiovascular magnetic resonance techniques.

Authors:  Andreas Schuster; Inga Grünwald; Amedeo Chiribiri; Richard Southworth; Masaki Ishida; Gunnar Hay; Nicole Neumann; Geraint Morton; Divaka Perera; Tobias Schaeffter; Eike Nagel
Journal:  J Cardiovasc Magn Reson       Date:  2010-09-17       Impact factor: 5.364

Review 7.  Myocardial first-pass perfusion cardiovascular magnetic resonance: history, theory, and current state of the art.

Authors:  Bernhard L Gerber; Subha V Raman; Krishna Nayak; Frederick H Epstein; Pedro Ferreira; Leon Axel; Dara L Kraitchman
Journal:  J Cardiovasc Magn Reson       Date:  2008-04-28       Impact factor: 5.364

  7 in total

北京卡尤迪生物科技股份有限公司 © 2022-2023.