Literature DB >> 12351301

Endotracheal intubation with a gum-elastic bougie in unanticipated difficult direct laryngoscopy: comparison of a blind technique versus indirect laryngoscopy with a laryngeal mirror.

Marian Weisenberg1, R David Warters, Benjamin Medalion, Peter Szmuk, Yehuda Roth, Tiberiu Ezri.   

Abstract

UNLABELLED: We evaluated the efficacy of intubation over a gum-elastic bougie by using either a blind technique or indirect laryngoscopy with a laryngeal mirror in patients with unexpected difficult direct laryngoscopy. In a prospective study, 60 consecutive patients with an unexpected Grade III or IV direct laryngoscopy were randomly allocated for intubation with a gum-elastic bougie either blindly (Group 1) or by indirect laryngoscopy with a laryngeal mirror (Group 2). We evaluated the failure rate of each method of intubation, complications related to either method, and the time required for intubation. Out of 725 patients evaluated over a 2-mo period, 60 patients (8.3%) had a Grade III laryngoscopy, and 30 of these were randomized into each group. There were 8 failed intubations in Group 1 compared with 1 failed intubation in Group 2 (P < 0.05). All eight failures in the blind intubation group ended with esophageal intubation. No additional complications were noted in either group. The time required for endotracheal intubation with each group was not significantly different (45 +/- 10 s versus 44 +/- 11 s). We conclude that intubation with a gum-elastic bougie had a lower failure rate using indirect laryngoscopy with a laryngeal mirror than a traditional blind technique. IMPLICATIONS: We evaluated the efficacy of intubation over a gum-elastic bougie by using either a blind technique or a laryngeal mirror. Intubation with a gum-elastic bougie had a lower failure rate using indirect laryngoscopy with a laryngeal mirror (P < 0.05) than a traditional blind technique.

Entities:  

Mesh:

Year:  2002        PMID: 12351301     DOI: 10.1097/00000539-200210000-00056

Source DB:  PubMed          Journal:  Anesth Analg        ISSN: 0003-2999            Impact factor:   5.108


  2 in total

1.  BMI as a Predictor for Potential Difficult Tracheal Intubation in Males.

Authors:  Alberto A Uribe; David A Zvara; Erika G Puente; Andrew J Otey; Jianying Zhang; Sergio D Bergese
Journal:  Front Med (Lausanne)       Date:  2015-06-04

2.  Comparison of the new flexible tip bougie catheter and standard bougie stylet for tracheal intubation by anesthesiologists in different difficult airway scenarios: a randomized crossover trial.

Authors:  Kurt Ruetzler; Jacek Smereka; Cristian Abelairas-Gomez; Michael Frass; Marek Dabrowski; Szymon Bialka; Hanna Misiolek; Tadeusz Plusa; Oliver Robak; Olga Aniolek; Jerzy Robert Ladny; Damian Gorczyca; Sanchit Ahuja; Lukasz Szarpak
Journal:  BMC Anesthesiol       Date:  2020-04-20       Impact factor: 2.217

  2 in total

北京卡尤迪生物科技股份有限公司 © 2022-2023.