Application of headspace solid-phase microextraction and gas chromatography-mass spectrometry for detection of the chemical warfare agent bis(2-chloroethyl) sulfide in soil.

Gregory L Kimm1, Gary L Hook, Philip A Smith.   

Abstract

A field expedient analytical method for detecting the chemical warfare agent (CWA) sulfur mustard as a soil contaminant was developed using solid-phase microextraction (SPME) and gas chromatography-mass spectrometry (GC-MS). Five commercially available SPME fibers were investigated to determine the optimal fiber, and extraction conditions. Polyacrylate and carbowax-divinylbenzene fiber coatings gave a statistically indistinguishable and best response compared to the other three types examined in a simple system studied without soil. The polyacrylate fiber coating was selected for study of a system in which sulfur mustard was spiked to an agricultural soil (Standard Reference Material 2709, San Joaquin type). With soil samples, the greatest sensitivity occurred by the addition of deionized water to spiked soil and extraction at ambient temperature for 20 min or longer. SPME sampling with GC-MS analyses afforded good reproducibility (relative standard deviation between 2 and 10%), and analyte concentrations as low as 237 ng/g were detected in soil (total ion chromatograms). As completed here, total time for sampling and analysis was just under 1 h, and use of organic solvents or special sample introduction equipment was avoided.

Entities:  

Mesh:

Substances:

Year:  2002        PMID: 12350113     DOI: 10.1016/s0021-9673(02)00999-8

Source DB:  PubMed          Journal:  J Chromatogr A        ISSN: 0021-9673            Impact factor:   4.759


  2 in total

1.  Hand-portable gas chromatograph-toroidal ion trap mass spectrometer (GC-TMS) for detection of hazardous compounds.

Authors:  Jesse A Contreras; Jacolin A Murray; Samuel E Tolley; Joseph L Oliphant; H Dennis Tolley; Stephen A Lammert; Edgar D Lee; Douglas W Later; Milton L Lee
Journal:  J Am Soc Mass Spectrom       Date:  2008-07-03       Impact factor: 3.109

2.  A choline oxidase amperometric bioassay for the detection of mustard agents based on screen-printed electrodes modified with Prussian Blue nanoparticles.

Authors:  Fabiana Arduini; Viviana Scognamiglio; Corrado Covaia; Aziz Amine; Danila Moscone; Giuseppe Palleschi
Journal:  Sensors (Basel)       Date:  2015-02-13       Impact factor: 3.576