Literature DB >> 12349981

Probing antigen-antibody binding processes by impedance measurements on ion-sensitive field-effect transistor devices and complementary surface plasmon resonance analyses: development of cholera toxin sensors.

Maya Zayats1, Oleg A Raitman, Vladimir I Chegel, Andrei B Kharitonov, Itamar Willner.   

Abstract

Impedance measurements on ISFET devices are employed to develop new immunosensors. The analysis of the transconductance curves recorded at variable frequencies, upon the formation of antigen-antibody complexes on the ISFET devices, allows determination of the biomaterial film thicknesses. Complementary surface plasmon resonance measurements of analogous biosensor systems, using Au-coated glass slides as support, reveal similar film thicknesses of the biomaterials and comparable detection limits. A dinitrophenyl antigen layer is immobilized on the ISFET gate as a sensing interface for the anti-dinitrophenyl antibody (anti-DNP-Ab). The anti-DNP-Ab is analyzed with a sensitivity that corresponds to 0.1 microg mL(-1). The assembly of the biotinylated anti-anti-DNP-Ab and avidin layers on the base anti-DNP-Ab layer is characterized by impedance measurements. The development of an ISFET-based sensor for the cholera toxin is described. The anti-cholera toxin antibody is immobilized on the ISFET device. The association of the cholera toxin (CT) to the antibody is monitored by the impedance measurements. The detection limit for analyzing CT is 1.0 x 10(-11) M.

Entities:  

Mesh:

Substances:

Year:  2002        PMID: 12349981     DOI: 10.1021/ac020312f

Source DB:  PubMed          Journal:  Anal Chem        ISSN: 0003-2700            Impact factor:   6.986


  5 in total

1.  Polarizability and Kerr constant of proteins by boundary element methods.

Authors:  Sergio R Aragon; David K Hahn
Journal:  Colloids Surf B Biointerfaces       Date:  2006-11-28       Impact factor: 5.268

2.  Detection of bacterial toxins with monosaccharide arrays.

Authors:  Miriam M Ngundi; Chris R Taitt; Scott A McMurry; Daniel Kahne; Frances S Ligler
Journal:  Biosens Bioelectron       Date:  2005-06-08       Impact factor: 10.618

3.  Quantitative detection of Vibrio cholera toxin by real-time and dynamic cytotoxicity monitoring.

Authors:  Dazhi Jin; Yun Luo; Min Zheng; Haijing Li; Jing Zhang; Melinda Stampfl; Xiao Xu; Gangqiang Ding; Yanjun Zhang; Yi-Wei Tang
Journal:  J Clin Microbiol       Date:  2013-09-18       Impact factor: 5.948

4.  Ion-sensitive field-effect transistor for biological sensing.

Authors:  Chang-Soo Lee; Sang Kyu Kim; Moonil Kim
Journal:  Sensors (Basel)       Date:  2009-09-07       Impact factor: 3.576

Review 5.  Nanotechnology-Based Surface Plasmon Resonance Affinity Biosensors for In Vitro Diagnostics.

Authors:  Riccarda Antiochia; Paolo Bollella; Gabriele Favero; Franco Mazzei
Journal:  Int J Anal Chem       Date:  2016-08-10       Impact factor: 1.885

  5 in total

北京卡尤迪生物科技股份有限公司 © 2022-2023.