Literature DB >> 12349937

Experimental and theoretical determination of dosimetric characteristics of IsoAid ADVANTAGE 125I brachytherapy source.

Ali S Meigooni1, Joshua L Hayes, Hualin Zhang, Keith Sowards.   

Abstract

125I brachytherapy sources are being used for interstitial implants in tumor sites such as the prostate. Recently, the ADVANTAGE 125I, Model IAI-125, source became commercially available for interstitial brachytherapy treatment. Dosimetric characteristics (dose rate constant, radial dose function, and anisotropy function) of this source were experimentally and theoretically determined, following the AAPM Task Group 43 recommendations. Derivation of the dose rate constant was based on recent NIST WAFAC calibration performed in accordance with their 1999 standard. Measurements were performed in Solid Water phantom using LiF thermoluminescent dosimeters. The theoretical calculations were performed in both Solid Water and water using the PTRAN Monte Carlo code. The results indicated that a dose rate constant of the new source in water was 0.98 +/- 0.03 cGy h(-1) U(-1). The radial dose function of the new source was measured in Solid Water and calculated both in water and Solid Water at distances up to 10.0 cm. The anisotropy function, F(r, theta), of the new source was measured and calculated in Solid Water at distances of 2 cm, 3 cm, 5 cm, and 7 cm and also was calculated in water at distances ranging from 1 cm to 7 cm from the source. From the anisotropy function, the anisotropy factors and anisotropy constant were derived. The anisotropy constant of the ADVANTAGE 125I source in water was found to be 0.97 +/- 0.03. The dosimetric characteristics of this new source compared favorably with those from the Amersham Health Model 6711 source. Complete dosimetric parameters of the new source are presented in this paper.

Entities:  

Mesh:

Substances:

Year:  2002        PMID: 12349937     DOI: 10.1118/1.1500395

Source DB:  PubMed          Journal:  Med Phys        ISSN: 0094-2405            Impact factor:   4.071


  10 in total

1.  Radiobiological effect induced by different activities of (125)I seed brachytherapy in a hepatocellular carcinoma model.

Authors:  Qing-Hong Qin; Bai-Sha Huang; Qi-Xing Tan; Wei-Ping Yang; Bin Lian; Chang-Yuan Wei
Journal:  Int J Clin Exp Med       Date:  2014-12-15

2.  RNA Nanoparticles Derived from Three-Way Junction of Phi29 Motor pRNA Are Resistant to I-125 and Cs-131 Radiation.

Authors:  Hui Li; Piotr G Rychahou; Zheng Cui; Fengmei Pi; B Mark Evers; Dan Shu; Peixuan Guo; Wei Luo
Journal:  Nucleic Acid Ther       Date:  2015-05-27       Impact factor: 5.486

3.  Brachytherapy Using Elastin-Like Polypeptides with (131)I Inhibit Tumor Growth in Rabbits with VX2 Liver Tumor.

Authors:  Xinpei Liu; Yiming Shen; Xuqian Zhang; Rui Lin; Qiang Jia; Yixiang Chang; Wenge Liu; Wentian Liu
Journal:  Dig Dis Sci       Date:  2016-06-13       Impact factor: 3.199

4.  Development of GATE Monte Carlo Code for Simulation and Dosimetry of New I-125 Seeds in Eye Plaque Brachytherapy.

Authors:  Payvand Taherparvar; Zeinab Fardi
Journal:  Nucl Med Mol Imaging       Date:  2021-01-11

5.  A comparison study on various low energy sources in interstitial prostate brachytherapy.

Authors:  Mahdi Bakhshabadi; Mahdi Ghorbani; Mohsen Khosroabadi; Courtney Knaup; Ali S Meigooni
Journal:  J Contemp Brachytherapy       Date:  2016-02-05

6.  Episcleral eye plaque dosimetry comparison for the Eye Physics EP917 using Plaque Simulator and Monte Carlo simulation.

Authors:  Leonard W Zimmermann; Ahmad Amoush; Douglas A Wilkinson
Journal:  J Appl Clin Med Phys       Date:  2015-11-08       Impact factor: 2.102

7.  Comparison of 16 mm OSU-Nag and COMS eye plaques.

Authors:  Hualin Zhang; Frederick Davidorf; Yujin Qi
Journal:  J Appl Clin Med Phys       Date:  2012-05-10       Impact factor: 2.102

8.  Cylindrical coordinate based TG-43U1 parameters for dose calculation around elongated brachytherapy sources.

Authors:  Shahid B Awan; Sharifeh A Dini; Manzoor Hussain; David Soleimani-Meigooni; Ali S Meigooni
Journal:  J Appl Clin Med Phys       Date:  2008-04-16       Impact factor: 2.102

9.  Comparison of TG-43 dosimetric parameters of brachytherapy sources obtained by three different versions of MCNP codes.

Authors:  Neda Zaker; Mehdi Zehtabian; Sedigheh Sina; Craig Koontz; Ali S Meigooni
Journal:  J Appl Clin Med Phys       Date:  2016-03-08       Impact factor: 2.102

10.  Monte Carlo calculations and experimental measurements of the TG-43U1-recommended dosimetric parameters of 125I (Model IR-Seed2) brachytherapy source.

Authors:  Sahar Sheikholeslami; Hasan Ali Nedaie; Mahdi Sadeghi; Hosein Pourbeigy; Sohrab Shahzadi; Mehdi Zehtabian; Mohsen Hasani; Ali S Meigooni
Journal:  J Appl Clin Med Phys       Date:  2016-07-08       Impact factor: 2.102

  10 in total

北京卡尤迪生物科技股份有限公司 © 2022-2023.