Literature DB >> 12324795

Efficacy of bacterial removal from instrumented root canals in vitro related to instrumentation technique and size.

Scott Rollison1, Frederic Barnett, Roy H Stevens.   

Abstract

OBJECTIVE: This in vitro investigation assessed the efficacy of removing radioactively labeled bacteria from infected canals with 2 engine-driven rotary nickel titanium instrumentation techniques differing in sequence and apical enlargement size. STUDY
DESIGN: A standard quantity of (3)H-thymidine-labeled Enterococcus faecalis (3.70 x 10(4) cpm, 2.0 x 10(7) colony-forming units) was used to inoculate the mesiobuccal canals of 50 extracted mandibular molars. The teeth were incubated for 5 days to allow infection of the surrounding dentin from the canals. Five of the teeth were used as controls to determine the number of cycles of irrigation and drying necessary to reduce the (3)H counts recovered from the canals to baseline levels. After this process, the unbound bacteria in the root canals of the remaining 45 teeth then were washed out with buffer until baseline levels of radioactivity were obtained. The mesiobuccal root of 1 of these 45 teeth was removed, decalcified, and digested, and the total radioactivity released from the root dentin was measured. Of the remaining 44 teeth, 22 then were instrumented with GT and Profile (Dentsply/Tulsa Dental Co, Tulsa, Okla) instruments to apical size #35 (group 1) and 22 teeth with Pow-R instruments (Moyco/Union Broach, York, Pa) to apical size #50 (group 2), in the presence of a standard quantity of phosphate-buffered saline solution placed in the canal. After instrumentation, the medium from each canal was collected with paper points and its radioactivity was counted with liquid scintillation spectrometry.
RESULTS: The mean (3)H level recovered with instrumentation of canals in group 1 was 75 cpm (+/- 29, standard deviation) and in group 2 was 123 cpm (+/- 50, standard deviation). A 2-tailed Mann-Whitney test indicated that the radioactivity of samples from group 2 was significantly higher than that of samples from group 1.
CONCLUSION: The results suggested that instrumentation to an apical size of #50, as performed with the Pow-R instruments, was more effective in debriding infected root canals than instrumentation to an apical size of #35, as performed with the GT and Profile instruments.

Entities:  

Mesh:

Substances:

Year:  2002        PMID: 12324795     DOI: 10.1067/moe.2002.126164

Source DB:  PubMed          Journal:  Oral Surg Oral Med Oral Pathol Oral Radiol Endod        ISSN: 1079-2104


  13 in total

1.  Comparison of Sealer Penetration by Using Different Irrigation Techniques - An In-vitro Study.

Authors:  Prabu Mahin Syed Ismail; Siddiq Ahamed; P B Sabiha; M Chandra Sekhar; Gopikrishna Moosani; S Nagalakshmi Reddy; N Upendranatha Reddy; C H Sumanthi
Journal:  J Clin Diagn Res       Date:  2016-12-01

2.  Shaping ability of rotary or reciprocating systems for oval root canal preparation: a micro-computed tomography study.

Authors:  Camila Galletti Espir; Camila Almeida Nascimento-Mendes; Juliane Maria Guerreiro-Tanomaru; Bruno Cavalini Cavenago; Marco Antonio Hungaro Duarte; Mário Tanomaru-Filho
Journal:  Clin Oral Investig       Date:  2018-03-10       Impact factor: 3.573

3.  Restorative outcomes for endodontically treated teeth in the Practitioners Engaged in Applied Research and Learning network.

Authors:  Howard Spielman; Scott B Schaffer; Mitchell G Cohen; Hongyu Wu; Donald A Vena; Damon Collie; Frederick A Curro; Van P Thompson; Ronald G Craig
Journal:  J Am Dent Assoc       Date:  2012-07       Impact factor: 3.634

4.  Influence of post type on periapical status: a prospective study in a Brazilian population.

Authors:  Guilherme da Luz-Silva; Bruna Muhlinberg Vetromilla; Tatiana Pereira-Cenci
Journal:  Clin Oral Investig       Date:  2021-07-07       Impact factor: 3.573

5.  Cleaning Effectiveness of Three NiTi Rotary Instruments: A Focus on Biomaterial Properties.

Authors:  Claudio Poggio; Alberto Dagna; Marco Chiesa; Riccardo Beltrami; Stefano Bianchi
Journal:  J Funct Biomater       Date:  2015-02-16

6.  Apical third enlargement of the root canal and its relationship with the repair of periapical lesions.

Authors:  Ronaldo Araújo Souza; João Costa Pinto Dantas; Paula Maciel Brandão; Suely Colombo; Maurício Lago; Marco Antônio Húngaro Duarte
Journal:  Eur J Dent       Date:  2012-10

7.  Chemomechanical preparation by hand instrumentation and by Mtwo engine-driven rotary files, an ex vivo study.

Authors:  Károly Krajczár; Zoltán Tigyi; Viktória Papp; Gyula Marada; Jeges Sára; Vilmos Tóth
Journal:  J Clin Exp Dent       Date:  2012-07-01

8.  Evaluation of the apical adaptation performance of various root canal instruments.

Authors:  K Tolga Ceyhanli; Murat Turkun; Necdet Erdilek; Cem Peskersoy; Timur Kose
Journal:  Eur J Dent       Date:  2013-09

9.  Cone-Beam Computed Tomography Comparison of Canal Transportation after Preparation with BioRaCe and Mtwo Rotary Instruments and Hand K-Flexofiles.

Authors:  Hadi Mokhtari; Mahdi Niknami; Aydin Sohrabi; Ehsan Habibivand; Hamid Reza Mokhtari Zonouzi; Saeed Rahimi; Vahid Zand
Journal:  Iran Endod J       Date:  2014-07-05

10.  Influence of Different Apical Preparations on Root Canal Cleanliness in Human Molars: a SEM Study.

Authors:  Gianluca Plotino; Nicola M Grande; Luigi Tocci; Luca Testarelli; Gianluca Gambarini
Journal:  J Oral Maxillofac Res       Date:  2014-07-01
View more

北京卡尤迪生物科技股份有限公司 © 2022-2023.