Reduction of the inflammatory response following coronary bypass grafting with total minimal extracorporeal circulation.

Yves Fromes1, Didier Gaillard, Olivier Ponzio, Maryline Chauffert, Marie-Françoise Gerhardt, Philippe Deleuze, Olivier M Bical.   

Abstract

OBJECTIVE: Cardiopulmonary bypass (CPB) is known to cause part of the systemic inflammatory reaction after cardiac surgery that can be responsible for organ failure. A novel technique based on a minimal extracorporeal circulation (MECC(R)) system has been evaluated with regard to the inflammatory response in a prospective study involving patients undergoing coronary artery bypass grafting.
METHODS: Sixty consecutive patients were randomly assigned to either standard normothermic CPB (n=30) or the MECC system, with a reduced priming volume, no aortic venting and no venous reservoir, excluding the blood-air interface (n=30). Specific evaluation of cytokine release (IL-1beta, IL-6, TNF-alpha), as well as neutrophil elastase secretion and beta-thromboglobulin release from platelets and S100 protein assay were performed. Serial blood samples were taken prior to the onset, after initiation, at the end and after weaning of the CPB; further samples were collected 6 and 24h after the end of the CPB.
RESULTS: All patients were similar with regards to pre- and intra-operative characteristics and clinical outcomes were comparable for both groups. MECC system allowed a reduced hemodilution with a mean drop of the hematocrit of 8.5 vs. 15.3% (P<0.05). Mononuclear phagocytes dropped in a more important manner under standard CPB conditions (247+/-151 vs. 419+/-168, P=0.002), but both groups demonstrated a rise in monocyte count at the end of the CBP. No significant release of IL-1beta was observed in either group. By the end of CPB, IL-6 levels were significantly lower in the MECC group (38.8+/-19.6 vs. 87.9+/-78.9, P=0.04), despite a higher monocyte count. Plasma levels of TNF-alpha rised significantly more during standard CPB than with the MECC system (17.8+/-15.4 vs. 10.1+/-5.6, P=0.002). With MECC, the neutrophil elastase release was reduced (72.7+/-47.9 vs. 219.6+/-103.4, P=0.001). Platelet count remained at higher values with the minimal compared to standard CPB. It is noteworthy to consider that beta-thromboglobulin levels showed slightly lower platelet activation in the MECC group at all times of CPB (110.5+/-55.6 vs. 134.7+/-46.8, P=0.10). The pattern of release of S100 protein showed higher values in patients undergoing standard CPB than after MECC.
CONCLUSIONS: The MECC system is suitable to maintain total extracorporeal circulation and demonstrates a lower inflammatory reaction when compared to standard CPB.

Entities:  

Mesh:

Substances:

Year:  2002        PMID: 12297167     DOI: 10.1016/s1010-7940(02)00372-x

Source DB:  PubMed          Journal:  Eur J Cardiothorac Surg        ISSN: 1010-7940            Impact factor:   4.191


  27 in total

Review 1.  Use of minimal invasive extracorporeal circulation in cardiac surgery: principles, definitions and potential benefits. A position paper from the Minimal invasive Extra-Corporeal Technologies international Society (MiECTiS).

Authors:  Kyriakos Anastasiadis; John Murkin; Polychronis Antonitsis; Adrian Bauer; Marco Ranucci; Erich Gygax; Jan Schaarschmidt; Yves Fromes; Alois Philipp; Balthasar Eberle; Prakash Punjabi; Helena Argiriadou; Alexander Kadner; Hansjoerg Jenni; Guenter Albrecht; Wim van Boven; Andreas Liebold; Fillip de Somer; Harald Hausmann; Apostolos Deliopoulos; Aschraf El-Essawi; Valerio Mazzei; Fausto Biancari; Adam Fernandez; Patrick Weerwind; Thomas Puehler; Cyril Serrick; Frans Waanders; Serdar Gunaydin; Sunil Ohri; Jan Gummert; Gianni Angelini; Volkmar Falk; Thierry Carrel
Journal:  Interact Cardiovasc Thorac Surg       Date:  2016-01-26

2.  Use of a soft reservoir bag in a fully heparin-coated closed-loop cardiopulmonary bypass system for distal aortic perfusion during aortic surgery.

Authors:  Norihiko Shiiya; Kenji Matsuzaki; Takashi Kunihara; Keishu Yasuda
Journal:  J Artif Organs       Date:  2005       Impact factor: 1.731

3.  Aortic valve replacement in a dialysis-dependent Jehovah's Witness: successful use of a minicircuit, microplegia, and multimodality blood conservation technique.

Authors:  Edson H Cheung; Steve W Sutton; Randy Marcel
Journal:  Proc (Bayl Univ Med Cent)       Date:  2007-01

4.  Miniaturized biocompatible cardiopulmonary bypass for the Fontan procedure.

Authors:  Keiichi Itatani; Kagami Miyaji; Takashi Miyamoto; Nobuyuki Inoue; Takahiro Tomoyasu; Satoshi Kohira; Hajime Sato; Kuniyoshi Ohara
Journal:  Surg Today       Date:  2010-11-03       Impact factor: 2.549

5.  Evaluation of hemodynamic and regional tissue perfusion effects of minimized extracorporeal circulation (MECC).

Authors:  Adrian Bauer; Claudius Diez; Jens Schubel; Nagi El-Shouki; Dietrich Metz; T Eberle; Harald Hausmann
Journal:  J Extra Corpor Technol       Date:  2010-03

6.  Minimal cardiopulmonary bypass attenuates neutrophil activation and cytokine release in coronary artery bypass grafting.

Authors:  Toshihiro Ohata; Masataka Mitsuno; Mitsuhiro Yamamura; Hiroe Tanaka; Yasuhiko Kobayashi; Masaaki Ryomoto; Yoshiteru Yoshioka; Yuji Miyamoto
Journal:  J Artif Organs       Date:  2007-06-20       Impact factor: 1.731

Review 7.  Influence of cirrhosis in cardiac surgery outcomes.

Authors:  Juan C Lopez-Delgado; Francisco Esteve; Casimiro Javierre; Josep L Ventura; Rafael Mañez; Elisabet Farrero; Herminia Torrado; David Rodríguez-Castro; Maria L Carrio
Journal:  World J Hepatol       Date:  2015-04-18

8.  Haemostasis alterations in coronary artery bypass grafting: comparison between the off-pump technique and a closed coated cardiopulmonary bypass system.

Authors:  Giuseppe Scrascia; Crescenzia Rotunno; Piero Guida; Manuela Conte; Lillà Amorese; Vito Margari; Luigi de Luca Tupputi Schinosa; Domenico Paparella
Journal:  Interact Cardiovasc Thorac Surg       Date:  2013-01-18

9.  Protective effect of silymarin during coronary artery bypass grafting surgery.

Authors:  Tagreed Altaei
Journal:  Exp Clin Cardiol       Date:  2012

Review 10.  The inflammatory response to miniaturised extracorporeal circulation: a review of the literature.

Authors:  Hunaid A Vohra; Robert Whistance; Amit Modi; Sunil K Ohri
Journal:  Mediators Inflamm       Date:  2010-01-13       Impact factor: 4.711