Literature DB >> 12296593

Comparison of 2 retentive systems for implant-supported overdentures: soft tissue management and evaluation of patient satisfaction.

Cuneyt Karabuda1, Tosun Tosun, Evren Ermis, Tayfun Ozdemir.   

Abstract

BACKGROUND: The aim of the present study was to compare the peri-implant soft tissue health status of implants supporting overdentures with bar attachments or ball attachments in the mandible, as well as patient satisfaction with these attachment types.
METHODS: The study included a Dolder bar group with 18 cases (43 implants) and a ball attachment group with 18 cases (51 implants). The mean function period in the Dolder bar group was 49 months (range: 12 to 72 months) and in the ball attachment group, the mean was 23 months (range: 12 to 40 months). Implants were clinically evaluated by using a modified plaque index (mPI), modified sulcus bleeding index (mSBI), and probing depths. Patient satisfaction with the treatment was recorded using a questionnaire.
RESULTS: mPI, probing depth, and mSBI did not statistically differ between groups (Mann-Whitney U test, P > 0.05). Patient satisfaction was similar with both retentive systems.
CONCLUSION: Within the limits of this study, we concluded that there was no significant difference between the 2 attachment types used for implant-supported overdentures with respect to the soft tissue health status or patient satisfaction.

Entities:  

Mesh:

Year:  2002        PMID: 12296593     DOI: 10.1902/jop.2002.73.9.1067

Source DB:  PubMed          Journal:  J Periodontol        ISSN: 0022-3492            Impact factor:   6.993


  3 in total

Review 1.  WITHDRAWN: Interventions for replacing missing teeth: different types of dental implants.

Authors:  Marco Esposito; Yasmin Ardebili; Helen V Worthington
Journal:  Cochrane Database Syst Rev       Date:  2019-10-10

Review 2.  Prosthodontic maintenance and peri-implant tissue conditions for telescopic attachment-retained mandibular implant overdenture: Systematic review and meta-analysis of randomized clinical trials.

Authors:  Ahmed Mohamed Keshk; Ahmed Yaseen Alqutaibi; Radhwan S Algabri; Mostafa S Swedan; Amal Kaddah
Journal:  Eur J Dent       Date:  2017 Oct-Dec

3.  Evaluation of two interforaminal implants and implant-assisted removable dentures on stress distribution: an in vitro study.

Authors:  Selda Arat Bilhan; Onur Geckili; Altug Cilingir; Ergun Bozdag; Hakan Bilhan
Journal:  J Korean Assoc Oral Maxillofac Surg       Date:  2019-08-28
  3 in total

北京卡尤迪生物科技股份有限公司 © 2022-2023.