Literature DB >> 12296576

One piece ultracompact totally implantable electromechanical total artificial heart for permanent use.

Setsuo Takatani1, Tohru Sakamoto, Katsuhiro Ohuchi, Makoto Nakamura, Tomohiro Mizuno, Hirokuni Arai.   

Abstract

An ultracompact, one piece, totally implantable electromechanical total artificial heart (TAH) has been developed as a permanent replacement for failing hearts. It consists of left and right pusher plate blood pumps (stroke volume 55 ml) made of titanium alloy (Ti-6Al-7Nb) sandwiching a miniaturized electromechanical actuator between them. The diameter of the TAH is 90 mm, with a thickness of 70 mm, yielding an overall volume of 400 ml. It weighs 450 g. Although it is miniaturized, it provided a maximum pump output of 8 L/min against a left afterload of 100 mm Hg. It required approximately 12 watts to provide a pump output of 6.5 L/min with maximum efficiency of 13.5%. To balance left and right flow, the right stroke length was made 10% shorter than the left, and an auxiliary compliance chamber was used to compensate for additional flow differences between them. Motor commutation pulses and a Hall effect pusher plate sensor signal were used in the controller to implement the left master alternate variable rate mode. The calf fitting study revealed excellent anatomic compatibility, and the first successful survivor was obtained in December 2001. Studies of system endurance and biocompatibility are required to ensure long-term reliability. This TAH is promising for permanent replacement of the failing heart as well as for bridge to heart transplantation for the smaller size group of end-stage cardiac patients.

Entities:  

Mesh:

Year:  2002        PMID: 12296576     DOI: 10.1097/00002480-200209000-00017

Source DB:  PubMed          Journal:  ASAIO J        ISSN: 1058-2916            Impact factor:   2.872


  4 in total

Review 1.  Mechanical circulatory support devices (MCSD) in Japan: current status and future directions.

Authors:  Setsuo Takatani; Hikaru Matsuda; Akihisa Hanatani; Chisato Nojiri; Kenji Yamazaki; Tadashi Motomura; Katsuhiro Ohuchi; Tohru Sakamoto; Takashi Yamane
Journal:  J Artif Organs       Date:  2005       Impact factor: 1.731

Review 2.  Development of mechanical circulatory support devices at the University of Tokyo.

Authors:  Yusuke Abe; Takashi Isoyama; Itsuro Saito; Shuichi Mochizuki; Minoru Ono; Hidemoto Nakagawa; Noriyuki Taniguchi; Norihiko Mitsumune; Ayaka Sugino; Mie Mitsui; Koki Takiura; Toshiya Ono; Akimasa Kouno; Tsuneo Chinzei; Shinichi Takamoto; Kou Imachi
Journal:  J Artif Organs       Date:  2007-06-20       Impact factor: 1.731

Review 3.  The ongoing quest for the first total artificial heart as destination therapy.

Authors:  Annemijn Vis; Maziar Arfaee; Husain Khambati; Mark S Slaughter; Jan F Gummert; Johannes T B Overvelde; Jolanda Kluin
Journal:  Nat Rev Cardiol       Date:  2022-06-06       Impact factor: 32.419

4.  Design and Evaluation of a Fully Implantable Control Unit for Blood Pumps.

Authors:  Kristin Unthan; Felix Gräf; Marco Laumen; Thomas Finocchiaro; Christoph Sommer; Hermann Lanmüller; Ulrich Steinseifer
Journal:  Biomed Res Int       Date:  2015-10-25       Impact factor: 3.411

  4 in total

北京卡尤迪生物科技股份有限公司 © 2022-2023.