Literature DB >> 12296399

Evaluation of an immunochromatography strip assay for the detection of Salmonella sp. from poultry.

D A Bautista1, S Elankumaran, J A Arking, R A Heckert.   

Abstract

The present study was conducted to evaluate the sensitivity and specificity of an immunochromatography-based diagnostic kit for Salmonella. The analytical sensitivity of the test when using pure colonies of different Salmonella species was in the range of 1 X 10(4) to 1 x 10(5) colony-forming units per milliliter. The strip detected 19 of 22 strains of Salmonella spp. but failed to detect S. worthington, S. choleraesuis var. kunzendorf and S. johannesburg. The strip did not detect 27 different enteric bacteria, including Escherichia coli O157:H7, Campylobacter jejuni, Shigella sonnei, and Vibrio parahaemolyticus. In direct testing of feces (n = 66) from chickens infected with Salmonella typhimurium, the strip had a sensitivity of 12.3% and a specificity of 100%. Evaluation of the strip assay (n = 510) after sample pre-enrichment in 2% buffered peptone water (BPW) yielded a sensitivity of 93.8% and specificity of 89% when compared to isolation and identification with xylose-lysine-tergitol 4 (XLT4) selective plating media. Subsequent enrichment in Hajna tetrathionate (TT) broth yielded a higher sensitivity (94.7%) and specificity (96.8%). The agreement (kappa) between the strip test and isolation was 0.004 in direct fecal testing, 0.82 in BPW, and 0.89 in TT broth. The assay could detect Salmonella sp. as early as 18-48 hours during pre-enrichment and enrichment compared to isolation on XLT4, which required an overnight incubation step for the presumptive isolation and identification of Salmonella.

Entities:  

Mesh:

Substances:

Year:  2002        PMID: 12296399     DOI: 10.1177/104063870201400514

Source DB:  PubMed          Journal:  J Vet Diagn Invest        ISSN: 1040-6387            Impact factor:   1.279


  2 in total

1.  A one-step homogeneous sandwich immunosensor for Salmonella detection based on magnetic nanoparticles (MNPs) and quantum Dots (QDs).

Authors:  Hua Kuang; Gang Cui; Xiujin Chen; Honghong Yin; Qianqian Yong; Liguang Xu; Chifang Peng; Libing Wang; Chuanlai Xu
Journal:  Int J Mol Sci       Date:  2013-04-22       Impact factor: 5.923

2.  Self-made Salmonella Pullorum agglutination antigen development and its potential practical application.

Authors:  B Yang; Q Niu; Y Yang; P Dai; T Yuan; S Xu; X Pan; Y Yang; G Zhu
Journal:  Poult Sci       Date:  2019-12-01       Impact factor: 3.352

  2 in total