Literature DB >> 12271402

Gadolinium-containing contrast media for radiographic examinations: a position paper.

Henrik S Thomsen1, Torsten Almèn, Sameh K Morcos.   

Abstract

Recently, it has been suggested that gadolinium-based contrast media could be used for radiological examinations in patients with significant renal impairment, previous severe generalized reaction to iodinated contrast media or thyroid disease about to undergo radioactive iodine treatment; however, the indications for and risks of using gadolinium agents in this way are not well known; hence, the Contrast Media Safety Committee of The European Society of Urogenital Radiology reviewed the literature to issue a position paper on this subject. A comprehensive literature review was performed and the resulting report was discussed at the Ninth European Symposium on Urogenital Radiology in Genoa, Italy, June 2002. Review of the literature indicates that according to experimental data on animals gadolinium-based contrast media have more nephrotoxic potential than iodinated contrast media in equivalent X-ray attenuating doses; therefore, gadolinium-based contrast media should not replace iodinated contrast media in patients with renal insufficiency for radiographic examinations. For patients with previous severe generalized reactions to iodinated contrast media, and in patients about to undergo thyroid treatment with radioactive iodine gadolinium-based contrast media in approved intravenous doses, up to 0.3 mmol/kg body weight will not give diagnostic radiographic information in most cases. Gadolinium-based contrast media are not approved for radiographic examinations.

Entities:  

Mesh:

Substances:

Year:  2002        PMID: 12271402     DOI: 10.1007/s00330-002-1628-3

Source DB:  PubMed          Journal:  Eur Radiol        ISSN: 0938-7994            Impact factor:   5.315


  29 in total

Review 1.  Recent hot topics in contrast media.

Authors:  Henrik S Thomsen
Journal:  Eur Radiol       Date:  2010-12-07       Impact factor: 5.315

2.  Off-label use of intravascular iodinated organic and MR contrast media.

Authors:  O Tamburrini; I Aprile; C Falcone; D Console; A Rotundo; A Rotondo
Journal:  Radiol Med       Date:  2010-10-27       Impact factor: 3.469

3.  Protein Nanospheres: Synergistic Nanoplatform-Based Probes for Multimodality Imaging.

Authors:  Michael A McDonald; Paul C Wang; Eliot L Siegel
Journal:  Proc SPIE Int Soc Opt Eng       Date:  2011-01-24

4.  Hysterosalpingography with gadolinium.

Authors:  Giovanni De Caro; Antonella Ferraiolo; Lara Castelletti; Paola Anserini; Franco Gorlero
Journal:  Eur Radiol       Date:  2004-12-04       Impact factor: 5.315

5.  Emergency coronary angiography with gadolinium in a patient with thyrotoxicosis, pulmonary embolism and persistent right atrial thrombi.

Authors:  Dierk Werner; Martin Misfeld; Matthias Regenfus; Hans-Hinrich Sievers; Bernhard Graf
Journal:  Clin Res Cardiol       Date:  2006-07-20       Impact factor: 5.460

6.  Safety of the long-time monthly triple dose of a Gd-based contrast agent.

Authors:  Francesco Sardanelli; Gianluigi Mancardi; Massimo Filippi
Journal:  Eur Radiol       Date:  2003-03-26       Impact factor: 5.315

7.  Nephrotoxicity of gadolinium-based contrast in the setting of renal artery intervention: retrospective analysis with 10-year follow-up.

Authors:  Edwin A Takahashi; David F Kallmes; Kristin C Mara; William S Harmsen; Sanjay Misra
Journal:  Diagn Interv Radiol       Date:  2018-11       Impact factor: 2.630

8.  Iodine contrast media doses equal-attenuating with gadolinium chelates at CT-aortography may have less risk of contrast-induced nephropathy and no risk of nephrogenic systemic fibrosis in azotaemic patients!

Authors:  Ulf Nyman; Barbara Elmståhl; Peter Leander; Torsten Almén
Journal:  Eur Radiol       Date:  2008-04-04       Impact factor: 5.315

9.  Gadolinium contrast media are more nephrotoxic than iodine media. The importance of osmolality in direct renal artery injections.

Authors:  Barbara Elmståhl; Ulf Nyman; Peter Leander; Chun-Ming Chai; Klaes Golman; Jonas Björk; Torsten Almén
Journal:  Eur Radiol       Date:  2006-08-05       Impact factor: 5.315

10.  Determination of infarct size in ex vivo swine hearts by multidetector computed tomography using gadolinium as contrast medium.

Authors:  Akos Varga-Szemes; Balazs Ruzsics; Robert Kirschner; Satinder P Singh; Pal Kiss; Brigitta C Brott; Tamas Simor; Ada Elgavish; Gabriel A Elgavish
Journal:  Invest Radiol       Date:  2012-05       Impact factor: 6.016

View more

北京卡尤迪生物科技股份有限公司 © 2022-2023.