Literature DB >> 12266

Size analysis of suspension inhalation aerosols by inertial separation methods.

G W Hallworth, U G Andrews.   

Abstract

The particle size distribution of beclomethasone dipropionate (BDP) aerosols delivered from pressurized metered dose suspension inhalers has been measured with three cascaded inertial separation instruments, the Casella Cascade Impactor, Multistage Liquid Impinger and Cascade Centripeter. Various methods for collecting the emitted aerosol before measurement have been examined. A bent glass tubular 'throat', used as a simulated oro-pharynx, collects 35-60% of the emitted dose by impingement of the wet spray cone in the throat. The aerosol passing through the throat has a similar but somewhat finer size distribution to that collected by firing directly into a large flask. The three cascaded instruments give similar results which in the Multistage Liquid Impinger also resemble those given by a salbutamol inhaler. The mass fraction (35-60%) emitted from the oral adaptor which is of a size capable of deep lung penetration ( less than 4 mum) is much higher than the fraction (10-16%) found in the lungs of dogs after inhalation of aerosol. The size distributions resemble those determined by microscopy and are expressed as aerodynamic sizes, thus showing that the particles approximate to unit density spheres. The performance of two simpler devices, Kirk's apparatus and the Harwell size selective air sampler are also assessed, the latter shows some promise for the simple evaluation of the respirable fraction of inhalation aerosols.

Entities:  

Mesh:

Substances:

Year:  1976        PMID: 12266     DOI: 10.1111/j.2042-7158.1976.tb04088.x

Source DB:  PubMed          Journal:  J Pharm Pharmacol        ISSN: 0022-3573            Impact factor:   3.765


  4 in total

1.  Assessment of the twin impinger for size measurement of metered-dose inhaler sprays.

Authors:  N C Miller; V A Marple; R K Schultz; W S Poon
Journal:  Pharm Res       Date:  1992-09       Impact factor: 4.200

2.  Optimized inhalation aerosols. II. Inertial testing methods for particle size analysis of pressurized inhalers.

Authors:  E M Phillips; P R Byron; K Fults; A J Hickey
Journal:  Pharm Res       Date:  1990-12       Impact factor: 4.200

3.  The influence of liposomal encapsulation on sodium cromoglycate pharmacokinetics in man.

Authors:  K M Taylor; G Taylor; I W Kellaway; J Stevens
Journal:  Pharm Res       Date:  1989-07       Impact factor: 4.200

4.  Pulmonary deposition and clinical response of 99mTc-labelled salbutamol delivered from a novel multiple dose powder inhaler.

Authors:  M Vidgren; J Arppe; P Vidgren; L Hyvärinen; P Vainio; M Silvasti; H Tukiainen
Journal:  Pharm Res       Date:  1994-09       Impact factor: 4.200

  4 in total