Literature DB >> 12243415

Lead(II)-selective electrode based on phenyl disulfide.

Abdolkarim Abbaspour1, Behnam Khajeh.   

Abstract

A PVC membrane electrode for lead ions based on phenyl disulfide as the membrane carrier was developed. The electrode exhibits a good Nernstian slope of 29.3 +/- 0.7 mV/decade and a linear range of 2.0 x 10(-6)-1.0 x 10(-2) M for Pb(NO3)2. The limit of detection is 1.2 x 10(-6) M. It has a response time of 45 s and can be used for at least fifty days without any divergence in potential. The proposed membrane sensor revealed high selectivity for Pb2+ over a wide variety of other metal ions and could be used in the pH range of 3.5-6.3. The electrode was used as an indicator electrode in potentiometric titration of lead ions.

Entities:  

Year:  2002        PMID: 12243415     DOI: 10.2116/analsci.18.987

Source DB:  PubMed          Journal:  Anal Sci        ISSN: 0910-6340            Impact factor:   2.081


  1 in total

1.  Fast Potentiometric Analysis of Lead in Aqueous Medium under Competitive Conditions Using an Acridono-Crown Ether Neutral Ionophore.

Authors:  Ádám Golcs; Viola Horváth; Péter Huszthy; Tünde Tóth
Journal:  Sensors (Basel)       Date:  2018-05-03       Impact factor: 3.576

  1 in total