Abstract

Performance characteristics of the Abbott LCx HIV RNA Quantitative Assay (LCx HIV) were established in a multicenter study comparing it with the manual (Amplicor v1.5) and automated (Cobas) ultra-sensitive Roche Amplicor HIV-1 Monitor v1.5, the Bayer Quantiplex HIV RNA 3.0 (bDNA v3.0), and the Organon NucliSens HIV QT 2.0 (NucliSens). Within-run precision of LCx HIV assessed in clinical specimens was SD log10 0.210 at approximately 50 copies/ml, and log10 0.133 at approximately 400 copies/ml. Total precision in a reconstituted type B HIV-1 RNA panel was SD log10 0.380 at 100 copies/ml, and SD log10 0.180 at 1000 copies/ml. Type B HIV-1 RNA sensitivity (1 ml input) assessed at a 50%, 75% and 95% detection rate ranged from 29 to 41, 54 to 75 and 94 to 176 copies/ml, respectively. Overall specificity in HIV seronegative individuals was 99.78%. Linear regression indicated close assay correlations and agreements for measurement of type B HIV-1 RNA. Pearson's correlations and (Log10LCx=aLog10x + b) linear regressions were 0.91 (y=0.892 Log10Amplicor + 0.595), 0.93 (y=0.827 Log10Cobas + 0.969), 0.93 (y=0.951 Log10bDNA + 0.550), and 0.79 (y=0.834 Log10NucliSens + 0.911). LCx HIV was least affected by the genetic variability of HIV-1. LCx HIV detected 99% of non-type B HIV-1 group M samples (subtypes A-G), Amplicor v1.5 detected 96%, and bDNA v3.0 detected 99%. The assays detected 10/11, 1/11 and 8/11, respectively of the HIV-1 group O samples. LCx HIV vs. Amplicor/bDNA Spearman's rank correlations for quantification of non-type B HIV-1 RNA were 0.76/0.84 (A), 0.93/0.93 (C), 0.73/0.99 (D), 0.86/0.98 (E), and 0.40/0.83 (group O). LCx HIV assays consistently detect and quantify type B, non-type B and group O HIV-1 RNA.

Entities:  

Mesh:

Substances:

Year:  2002        PMID: 12241017     DOI: 10.1515/CCLM.2002.120

Source DB:  PubMed          Journal:  Clin Chem Lab Med        ISSN: 1434-6621            Impact factor:   3.694


  3 in total

1.  Comparison of LCx with other current viral load assays for detecting and quantifying human immunodeficiency virus type 1 RNA in patients infected with the circulating recombinant form A/G (CRF02).

Authors:  Alessandra Amendola; Licia Bordi; Claudio Angeletti; Enrico Girardi; Giuseppe Ippolito; Maria R Capobianchi
Journal:  J Clin Microbiol       Date:  2004-02       Impact factor: 5.948

2.  Comparison of the LCx human immunodeficiency virus (HIV) RNA quantitative, RealTime HIV, and COBAS AmpliPrep-COBAS TaqMan assays for quantitation of HIV type 1 RNA in plasma.

Authors:  Vincent Foulongne; Brigitte Montes; Marie-Noelle Didelot-Rousseau; Michel Segondy
Journal:  J Clin Microbiol       Date:  2006-08       Impact factor: 5.948

3.  Impact of human immunodeficiency virus type 1 (HIV-1) genetic diversity on performance of four commercial viral load assays: LCx HIV RNA Quantitative, AMPLICOR HIV-1 MONITOR v1.5, VERSANT HIV-1 RNA 3.0, and NucliSens HIV-1 QT.

Authors:  Priscilla Swanson; Carmen de Mendoza; Yagnya Joshi; Alan Golden; Richard L Hodinka; Vincent Soriano; Sushil G Devare; John Hackett
Journal:  J Clin Microbiol       Date:  2005-08       Impact factor: 5.948