Literature DB >> 12239683

Self-reinforced bioabsorbable versus metallic fixation systems for metacarpal and phalangeal fractures: a biomechanical study.

Eero Waris1, Nureddin Ashammakhi, Timo Raatikainen, Pertti Törmälä, Seppo Santavirta, Yrjö T Konttinen.   

Abstract

Bioabsorbable fixation devices offer a useful option to treat small bone fractures of the hand if the prerequisite of reliable and stable osteofixation is met. We compared the stabilities of various bioabsorbable fixation devices with metallic fixation devices by using an oblique osteotomy model in radial to ulnar orientation. The 1.5-mm, self-reinforced, poly-L-lactide (SR-PLLA) pins provided fixation rigidity comparable with 1.5-mm K-wires in dorsal and palmar apex bending, whereas in lateral apex bending and in torsion the rigidity was equal to that of 1.25-mm K-wires. The 2.0-mm, self-reinforced, poly-L/DL-lactide (SR-P(L/DL)LA) 70/30 screws provided rigidity comparable with that of 1.5-mm K-wires in all testing modes. The bioabsorbable plate considerably enhanced the bending stabilities of the fixation system, but a single interfragmentary screw provided only limited rotational rigidity. The results show that by using ultra-high strength self-reinforced implants adequate fixation stability for hand fracture fixation can be achieved.

Entities:  

Mesh:

Substances:

Year:  2002        PMID: 12239683     DOI: 10.1053/jhsu.2002.35082

Source DB:  PubMed          Journal:  J Hand Surg Am        ISSN: 0363-5023            Impact factor:   2.230


  7 in total

1.  Delayed foreign-body reaction to absorbable implants in metacarpal fracture treatment.

Authors:  Panagiotis K Givissis; Stavros I Stavridis; Panayiotis J Papagelopoulos; Petros D Antonarakos; Anastasios G Christodoulou
Journal:  Clin Orthop Relat Res       Date:  2010-05-15       Impact factor: 4.176

2.  Biomechanical evaluation of metacarpal fracture fixation: application of a 90° internal fixation model.

Authors:  Andrew J Watt; Randal P Ching; Jerry I Huang
Journal:  Hand (N Y)       Date:  2015-03

3.  Surgical Fixation of Metacarpal Shaft Fractures Using Absorbable Implants: A Systematic Review of the Literature.

Authors:  Jessica Hazan; Alain Joe Azzi; Stephanie Thibaudeau
Journal:  Hand (N Y)       Date:  2018-09-21

4.  Increased Runx2 expression associated with enhanced Wnt signaling in PDLLA internal fixation for fracture treatment.

Authors:  Zhuoyan Ling; Lei Wu; Gaolong Shi; Li Chen; Qirong Dong
Journal:  Exp Ther Med       Date:  2017-03-10       Impact factor: 2.447

5.  Plating of metacarpal fractures with locked or nonlocked screws, a biomechanical study: how many cortices are really necessary?

Authors:  Cameron Barr; Anthony W Behn; Jeffrey Yao
Journal:  Hand (N Y)       Date:  2013-12

6.  The Efficacy of Transverse Fixation and Early Exercise in the Treatment of Fourth Metacarpal Bone Fractures.

Authors:  Suk-Ho Moon; Hak-Soo Kim; Sung-No Jung; Ho Kwon
Journal:  Arch Plast Surg       Date:  2016-03-18

7.  Long-Term Functional Results of Intra- and Extra-Articular Hand Fractures Treatment With Titanium Miniature Plates and Screws With Minimum Follow-Up of 24 Months.

Authors:  Sokratis Varitimidis; Zoe Dailiana; Dimitrios Agorastakis; Apostolos Fyllos; Aristeidis Zibis; Michael Hantes; Konstantinos Malizos
Journal:  Cureus       Date:  2021-06-04
  7 in total