STATEMENT OF PROBLEMS: Specification 25 of the American Dental Association (ADA) states that final setting expansion measurements of improved dental stone are made 2 hours after mixing. In a limited pilot study on selected type IV and V dental stones, measurements showed delayed linear expansion or early contraction continuing up to 120 hours.
PURPOSE: The objectives of this in vitro study were to measure the linear setting expansion of 6 ADA type IV and V dental stones, to compare their expansion at 2 hours relative to ADA Specification 25, and to characterize expansion changes up to 120 hours.
MATERIAL AND METHODS: The improved dental stones tested in this study were Die-Keen, Jade Stone, Vel-Mix, ResinRock, Fuji Rock, and Silky Rock. Mixing was performed in accordance with a standardized technique and the manufacturers' instructions. The mixes were poured into an electronic expansion-measuring device, and setting expansion values were continuously measured and recorded for 120 hours. The collected data were subjected to a 2-way repeated-measures multivariate analysis of variance at alpha=.05. Planned comparisons between the 2-hour experimental and 2-hour manufacturer expansion values were made at the 95% confidence interval.
RESULTS: All stones showed higher mean linear expansion values at 120 hours than at 2 hours. Expansion was essentially complete at 96 hours for all stones except ResinRock. Die-Keen exhibited the highest total mean setting expansion (0.35% +/- 0.013%), and Silky Rock exhibited the lowest mean linear expansion (0.14% +/- 0.008%) at 120 hours. Multivariate analysis of variance revealed significant interactions between stone and time (P<.0001). Mean expansion values at 2 hours were comparable to those stated by the manufacturer except for Die-Keen and Jade Stone.
CONCLUSION: Within the parameters of this study, all dental stones tested exhibited continued expansion while setting under clinical conditions. The amount of expansion varied significantly among the materials, with 22% to 71% of the expansion occurring after 2 hours. Die-Keen exhibited the highest total mean expansion but had the least amount of expansion after 2 hours; both Die-Keen and Silky Rock remained stable after 72 hours.

Mesh:

Substances:

Year:  2002        PMID: 12239476

Source DB:  PubMed          Journal:  J Prosthet Dent        ISSN: 0022-3913            Impact factor:   3.426


  4 in total

1.  A Comparative Evaluation of Accuracy of the Dies Affected by Tray Type, Material Viscosity, and Pouring Sequence of Dual and Single Arch Impressions- An In vitro Study.

Authors:  Poonam R Kulkarni; Rahul S Kulkarni; Rupal J Shah; Rahul Chhajlani; Bhuwan Saklecha; Kavita Maru
Journal:  J Clin Diagn Res       Date:  2017-04-01

2.  Accuracy of Digital Impressions and Fitness of Single Crowns Based on Digital Impressions.

Authors:  Xin Yang; Pin Lv; Yihong Liu; Wenjie Si; Hailan Feng
Journal:  Materials (Basel)       Date:  2015-06-29       Impact factor: 3.623

3.  In vitro evaluation of the precision of working casts for implant-supported restoration with multiple abutments.

Authors:  Anderson Almeida Castilho; Alberto Noriyuki Kojima; Sarina Maciel Braga Pereira; Diego Klee de Vasconcellos; Marcos Koiti Itinoche; Renata Faria; Marco Antonio Bottino
Journal:  J Appl Oral Sci       Date:  2007-06       Impact factor: 2.698

4.  Accuracy of fit of implant-supported bars fabricated on definitive casts made by different dental stones.

Authors:  Ioannis Kioleoglou; Argirios Pissiotis; Michalakis Konstantinos
Journal:  J Clin Exp Dent       Date:  2018-03-01
  4 in total

北京卡尤迪生物科技股份有限公司 © 2022-2023.