Literature DB >> 12234829

Respiratory variations of aortic VTI: a new index of hypovolemia and fluid responsiveness.

Michel Slama1, Henri Masson, Jean-Louis Teboul, Marie-Luce Arnout, Dinko Susic, Edward Frohlich, Michel Andrejak.   

Abstract

In 12 mechanically ventilated and anesthetized rabbits, we investigated whether the magnitude of respiratory changes in the aortic velocity time integral (VTI(Ao)), recorded by transthoracic echocardiography (TTE) during a stepwise blood withdrawal and restitution, could be used as a reliable indicator of volume depletion and responsiveness. At each step, left and right ventricular dimensions and the aortic diameter and VTI(Ao) were recorded to calculate stroke volume (SV) and cardiac output (CO). Respiratory changes of VTI(Ao) (maximal - minimal values divided by their respective means) were calculated. The amount of blood withdrawal correlated negatively with left and right ventricular diastolic diameters, VTI(Ao), SV, and CO and correlated directly with respiratory changes of VTI(Ao). Respiratory VTI(Ao) variations (but not other parameters) at the last blood withdrawal step was also correlated with changes in SV after blood restitution (r = 0.83, P < 0.001). In conclusion, respiratory variations in VTI(Ao) using TTE appear to be a sensitive index of blood volume depletion and restitution. This dynamic parameter predicted fluid responsiveness more reliably than static markers of cardiac preload.

Entities:  

Mesh:

Year:  2002        PMID: 12234829     DOI: 10.1152/ajpheart.00308.2002

Source DB:  PubMed          Journal:  Am J Physiol Heart Circ Physiol        ISSN: 0363-6135            Impact factor:   4.733


  37 in total

1.  Monitoring of respiratory variations of aortic blood flow velocity using esophageal Doppler.

Authors:  Michel Slama; Henri Masson; Jean-Louis Teboul; Marie-Luce Arnould; Rachida Nait-Kaoudjt; Bouchra Colas; Marcel Peltier; Christophe Tribouilloy; Dinko Susic; Edward Frohlich; Michel Andréjak
Journal:  Intensive Care Med       Date:  2004-03-05       Impact factor: 17.440

Review 2.  Echocardiography in the critically ill: current and potential roles.

Authors:  S Price; E Nicol; D G Gibson; T W Evans
Journal:  Intensive Care Med       Date:  2005-11-16       Impact factor: 17.440

3.  Bedside echocardiographic evaluation of hemodynamics in sepsis: is a qualitative evaluation sufficient?

Authors:  Antoine Vieillard-Baron; Cyril Charron; Karim Chergui; Olivier Peyrouset; François Jardin
Journal:  Intensive Care Med       Date:  2006-07-20       Impact factor: 17.440

4.  Recent publications by ochsner authors.

Authors: 
Journal:  Ochsner J       Date:  2003

5.  Echocardiography in the intensive care unit: beyond "eyeballing". A plea for the broader use of the aortic velocity-time integral measurement.

Authors:  Bernard Cholley
Journal:  Intensive Care Med       Date:  2019-04-17       Impact factor: 17.440

6.  Echocardiography to guide fluid therapy in critically ill patients: check the heart and take a quick look at the lungs.

Authors:  Federico Franchi; Luigi Vetrugno; Sabino Scolletta
Journal:  J Thorac Dis       Date:  2017-03       Impact factor: 2.895

Review 7.  Heart-Lung interaction in spontaneous breathing subjects: the basics.

Authors:  Sheldon Magder
Journal:  Ann Transl Med       Date:  2018-09

Review 8.  Respiratory variations in the arterial pressure during mechanical ventilation reflect volume status and fluid responsiveness.

Authors:  Azriel Perel; Reuven Pizov; Shamay Cotev
Journal:  Intensive Care Med       Date:  2014-04-16       Impact factor: 17.440

Review 9.  Echocardiography in the intensive care unit: from evolution to revolution?

Authors:  Antoine Vieillard-Baron; Michel Slama; Bernard Cholley; Gérard Janvier; Philippe Vignon
Journal:  Intensive Care Med       Date:  2007-11-09       Impact factor: 17.440

10.  Brachial artery peak velocity variation to predict fluid responsiveness in mechanically ventilated patients.

Authors:  Manuel Ignacio Monge García; Anselmo Gil Cano; Juan Carlos Díaz Monrové
Journal:  Crit Care       Date:  2009-09-03       Impact factor: 9.097

View more

北京卡尤迪生物科技股份有限公司 © 2022-2023.