Literature DB >> 12234465

Flow injection fluorescence immunoassay for gentamicin using sol-gel-derived mesoporous biomaterial.

Huang-Hao Yang1, Qing-Zhi Zhu, Hui-Ying Qu, Xiao-Lan Chen, Ma-Tai Ding, Jin-Gou Xu.   

Abstract

Sol-gel-derived mesoporous biomaterials were used for the first time in the flow-injection fluorescence immunoassay system. Anti-gentamicin antibody was immobilized in a mesoporous sol-gel material using tetramethoxysilane as a precursor and poly(ethylene glycol) as a template. The sol-gel glass was used to develop an immunoaffinity column for the flow-injection immunoassay of gentamicin. Little unspecific adsorption of gentamicin on the sol-gel and no antibody leaching under harsh elution conditions were found. The immunoassay is based on the competition between gentamicin and fluorescein isothiocyanate-labeled gentamicin for a limited number of encapsulated antibody binding sites. NaOH solution of 5 x 10(-3)mol/L is used for the regeneration of encapsulated antibody binding sites after each measurement, which allows the immunoreactor to be used for up to 20 times without any loss of reactivity. Sample preconcentration is not needed and a single assay can be performed within 10 min. The calibration for gentamicin has a working range of 250-5000 ng/mL with a detection limit of 200 ng/mL, which is close to that of the fluorescence immunoassay and fluorescence polarization immunoassay using the same reactants. Comparison of the results from this method with that obtained from HPLC showed an excellent correlation.

Entities:  

Mesh:

Substances:

Year:  2002        PMID: 12234465     DOI: 10.1016/s0003-2697(02)00222-1

Source DB:  PubMed          Journal:  Anal Biochem        ISSN: 0003-2697            Impact factor:   3.365


  5 in total

Review 1.  Immunoaffinity chromatography: an introduction to applications and recent developments.

Authors:  Annette C Moser; David S Hage
Journal:  Bioanalysis       Date:  2010-04       Impact factor: 2.681

Review 2.  Chromatographic immunoassays: strategies and recent developments in the analysis of drugs and biological agents.

Authors:  Ryan Matsuda; Elliott Rodriguez; Doddavenkatanna Suresh; David S Hage
Journal:  Bioanalysis       Date:  2015-11-16       Impact factor: 2.681

3.  Immunoassay Methods and their Applications in Pharmaceutical Analysis: Basic Methodology and Recent Advances.

Authors:  Ibrahim A Darwish
Journal:  Int J Biomed Sci       Date:  2006-09

4.  Sol-Gel Entrapped Levonorgestrel Antibodies: Activity and Structural Changes as a Function of Different Polymer Formats.

Authors:  Moran Shalev; Altstein Miriam
Journal:  Materials (Basel)       Date:  2011-02-25       Impact factor: 3.623

Review 5.  3D-Printed Immunosensor Arrays for Cancer Diagnostics.

Authors:  Mohamed Sharafeldin; Karteek Kadimisetty; Ketki S Bhalerao; Tianqi Chen; James F Rusling
Journal:  Sensors (Basel)       Date:  2020-08-12       Impact factor: 3.576

  5 in total

北京卡尤迪生物科技股份有限公司 © 2022-2023.