OBJECTIVE: To evaluate the effectiveness of adding outlet views to the four chamber view in routine prenatal ultrasound screening for major congenital heart defects (CHD) as performed by trained sonographers, and to compare the procedure with current practice. DESIGN AND
SETTING: Prospective observational study at a London teaching hospital. PARTICIPANTS AND METHODS: 9277 women booked at a single institution (80% had first trimester nuchal translucency measurement) due to have routine fetal cardiac screening using the four chamber and outflow tract views at > 18 weeks of gestation. MAIN OUTCOME MEASURE: Identification of major CHD in chromosomally normal and abnormal pregnancies antenatally or postnatally.
RESULTS: There were 40 abnormalities (4.3/1000), of which 30 were chromosomally normal (3.3/1000). The overall antenatal detection rate was 75% (95% confidence interval (CI) 59% to 87%) and 70% (95% CI 51% to 85%) for euploid pregnancies. Abnormal cardiac views accounted for 70% of all prenatal diagnoses, 30% of which were made at < or = 18 weeks. The sensitivity of cardiac views during the first scan at > 18 weeks was 52%. Of all patients undergoing nuchal translucency screening, 34 had major CHD, nine with increased nuchal translucency (26.5%). Factors influencing the results of this screening programme were training and audit of operators, adequate equipment for antenatal examination, ease of access, and low threshold for referral to specialised fetal echocardiography.
CONCLUSION: Adding ventricular outlet views to the four chamber assessment of the heart at routine fetal anomaly scans at > 18 weeks is the most effective technique to detect CHD prenatally. The success of such a programme depends on an infrastructure committed to continuous in house training of obstetric ultrasonographers coupled with feedback from specialised fetal cardiologists, as well as adequate resource allocation to obstetric hospitals involved with antenatal screening.

Entities:  

Mesh:

Year:  2002        PMID: 12231598      PMCID: PMC1767391          DOI: 10.1136/heart.88.4.387

Source DB:  PubMed          Journal:  Heart        ISSN: 1355-6037            Impact factor:   5.994


  27 in total

1.  Extended fetal echocardiographic examination for detecting cardiac malformations in low risk pregnancies.

Authors:  R Achiron; J Glaser; I Gelernter; J Hegesh; S Yagel
Journal:  BMJ       Date:  1992-03-14

2.  Congenital heart disease in 56,109 births. Incidence and natural history.

Authors:  S C Mitchell; S B Korones; H W Berendes
Journal:  Circulation       Date:  1971-03       Impact factor: 29.690

3.  Limitations of using first-trimester nuchal translucency measurement in routine screening for major congenital heart defects.

Authors:  E Mavrides; F Cobian-Sanchez; A Tekay; G Moscoso; S Campbell; B Thilaganathan; J S Carvalho
Journal:  Ultrasound Obstet Gynecol       Date:  2001-02       Impact factor: 7.299

4.  Prenatal diagnosis of congenital heart disease in the northern region of England: benefits of a training programme for obstetric ultrasonographers.

Authors:  S Hunter; A Heads; J Wyllie; S Robson
Journal:  Heart       Date:  2000-09       Impact factor: 5.994

5.  Current and potential impact of fetal diagnosis on prevalence and spectrum of serious congenital heart disease at term in the UK. British Paediatric Cardiac Association.

Authors:  C Bull
Journal:  Lancet       Date:  1999-10-09       Impact factor: 79.321

6.  A possible increase in the incidence of congenital heart defects among the offspring of affected parents.

Authors:  V Rose; R J Gold; G Lindsay; M Allen
Journal:  J Am Coll Cardiol       Date:  1985-08       Impact factor: 24.094

7.  Congenital heart disease in a cohort of 19,502 births with long-term follow-up.

Authors:  J I Hoffman; R Christianson
Journal:  Am J Cardiol       Date:  1978-10       Impact factor: 2.778

8.  Familial recurrence of congenital heart disease in a prospective series of mothers referred for fetal echocardiography.

Authors:  L D Allan; D C Crawford; S K Chita; R H Anderson; M J Tynan
Journal:  Am J Cardiol       Date:  1986-08-01       Impact factor: 2.778

Review 9.  Maternal drugs and congenital heart disease.

Authors:  S Zierler
Journal:  Obstet Gynecol       Date:  1985-02       Impact factor: 7.661

10.  Effectiveness of routine ultrasonography in detecting fetal structural abnormalities in a low risk population.

Authors:  L S Chitty; G H Hunt; J Moore; M O Lobb
Journal:  BMJ       Date:  1991-11-09
View more
  50 in total

1.  Prospective evaluation of the fetal heart using Fetal Intelligent Navigation Echocardiography (FINE).

Authors:  M Garcia; L Yeo; R Romero; D Haggerty; I Giardina; S S Hassan; T Chaiworapongsa; E Hernandez-Andrade
Journal:  Ultrasound Obstet Gynecol       Date:  2016-03-10       Impact factor: 7.299

2.  A novel algorithm for comprehensive fetal echocardiography using 4-dimensional ultrasonography and tomographic imaging.

Authors:  Jimmy Espinoza; Juan Pedro Kusanovic; Luís F Gonçalves; Jyh Kae Nien; Sonia Hassan; Wesley Lee; Roberto Romero
Journal:  J Ultrasound Med       Date:  2006-08       Impact factor: 2.153

3.  Four-chamber view and 'swing technique' (FAST) echo: a novel and simple algorithm to visualize standard fetal echocardiographic planes.

Authors:  L Yeo; R Romero; C Jodicke; G Oggè; W Lee; J P Kusanovic; E Vaisbuch; S Hassan
Journal:  Ultrasound Obstet Gynecol       Date:  2011-03-02       Impact factor: 7.299

4.  Simple targeted arterial rendering (STAR) technique: a novel and simple method to visualize the fetal cardiac outflow tracts.

Authors:  L Yeo; R Romero; C Jodicke; S K Kim; J M Gonzalez; G Oggè; W Lee; J P Kusanovic; E Vaisbuch; S Hassan
Journal:  Ultrasound Obstet Gynecol       Date:  2011-03-02       Impact factor: 7.299

5.  A systematic approach to the use of the multiplanar display in evaluation of abnormal vascular connections to the fetal heart using 4-dimensional ultrasonography.

Authors:  Jimmy Espinoza; Sonia S Hassan; Francesca Gotsch; Juan Pedro Kusanovic; Wesley Lee; Offer Erez; Luís F Gonçalves; Mary Lou Schoen; Roberto Romero
Journal:  J Ultrasound Med       Date:  2007-11       Impact factor: 2.153

6.  The role of the sagittal view of the ductal arch in identification of fetuses with conotruncal anomalies using 4-dimensional ultrasonography.

Authors:  Jimmy Espinoza; Roberto Romero; Juan Pedro Kusanovic; Francesca Gotsch; Offer Erez; Wesley Lee; Luís F Gonçalves; Mary Lou Schoen; Sonia S Hassan
Journal:  J Ultrasound Med       Date:  2007-09       Impact factor: 2.153

7.  Prenatal detection of congenital heart disease: time for a breakthrough.

Authors:  Karim A Diab; Sawsan Awad
Journal:  Pediatr Cardiol       Date:  2014-01       Impact factor: 1.655

8.  Genetic counseling throughout the life cycle.

Authors:  Leslie J Ciarleglio; Robin L Bennett; Jennifer Williamson; Jessica B Mandell; Joan H Marks
Journal:  J Clin Invest       Date:  2003-11       Impact factor: 14.808

9.  Prenatal diagnosis of transposition of the great arteries over a 20-year period: improved but imperfect.

Authors:  M C Escobar-Diaz; L R Freud; A Bueno; D W Brown; K G Friedman; D Schidlow; S Emani; P J Del Nido; W Tworetzky
Journal:  Ultrasound Obstet Gynecol       Date:  2015-04-30       Impact factor: 7.299

Review 10.  Fetal echocardiography: where are we?

Authors:  Anita Saxena; N Reeni Soni
Journal:  Indian J Pediatr       Date:  2005-07       Impact factor: 1.967

View more

北京卡尤迪生物科技股份有限公司 © 2022-2023.