Literature DB >> 12231307

Corneal asphericity after hyperopic laser in situ keratomileusis.

Chun Chen Chen1, Alexander Izadshenas, M Ali Asghar Rana, Dimitri T Azar.   

Abstract

PURPOSE: To analyze corneal asphericity after hyperopic laser in situ keratomileusis (LASIK) and its relationship to the clinical outcomes.
SETTING: Corneal and Refractive Surgery Service, Massachusetts Eye and Ear Infirmary, Boston, Massachusetts, USA.
METHODS: In a retrospective case series, 23 patients (33 eyes) with hyperopia or hyperopic astigmatism who had LASIK were evaluated. A computer program (Holladay Diagnostic Summary, EyeSys Laboratories) was used to analyze corneal asphericity (Q) before and after LASIK. Corneal asphericity was evaluated to determine the association with the postoperative refractive error, best spectacle-corrected visual acuity (BSCVA), uncorrected visual acuity (UCVA), achieved refractive correction, mean corneal power (K), refractive yield (achieved/attempted correction), and keratometric yield (change in keratometry/attempted correction).
RESULTS: After hyperopic LASIK, all corneas exhibited increased negative central Q. The postoperative corneal radius of curvature, BSCVA, and refractive and keratometric yields were not significantly correlated with the preoperative Q values. The asphericity change, Delta Q, was highly correlated with the achieved correction (r = 0.747, P <.0001). The postoperative Q value correlated well with the preoperative value (r = 0.534, P <.05) and the achieved correction (r = 0.601, P <.05) but not with the Delta Q. Neither the postoperative Q nor the Delta Q was correlated with the spherical equivalent, K, BSCVA, or UCVA.
CONCLUSIONS: Asphericity may be a useful quantitative descriptor of the corneal optical contour after hyperopic LASIK. Negative central Q increased after hyperopic LASIK, especially when greater degrees of refractive correction were attempted.

Entities:  

Mesh:

Year:  2002        PMID: 12231307     DOI: 10.1016/s0886-3350(02)01541-9

Source DB:  PubMed          Journal:  J Cataract Refract Surg        ISSN: 0886-3350            Impact factor:   3.351


  7 in total

1.  Hyperopic Q-optimized algorithms: a theoretical study on factors influencing optical quality.

Authors:  Jose R Jiménez; Aixa Alarcón; Rosario G Anera; L Jiménez Del Barco
Journal:  Biomed Opt Express       Date:  2017-02-06       Impact factor: 3.732

2.  Pilot study of hyperopic LASIK using the solid-state laser technology.

Authors:  David P Piñero; Francisco J Blanes-Mompó; Pedro Ruiz-Fortes; Rafael J Pérez-Cambrodí; Antonio Alzamora-Rodríguez
Journal:  Graefes Arch Clin Exp Ophthalmol       Date:  2012-10-05       Impact factor: 3.117

3.  Optics of conductive keratoplasty: implications for presbyopia management.

Authors:  Peter S Hersh
Journal:  Trans Am Ophthalmol Soc       Date:  2005

4.  Cryopreservation of extracted corneal lenticules after small incision lenticule extraction for potential use in human subjects.

Authors:  Sri Ganesh; Sheetal Brar; Pallavi A Rao
Journal:  Cornea       Date:  2014-12       Impact factor: 2.651

5.  Comparison of ocular higher-order aberrations after SMILE and Wavefront-guided Femtosecond LASIK for myopia.

Authors:  Xiaoqin Chen; Yan Wang; Jiamei Zhang; Shun-Nan Yang; Xiaojing Li; Lin Zhang
Journal:  BMC Ophthalmol       Date:  2017-04-07       Impact factor: 2.209

6.  Role of percent peripheral tissue ablated on refractive outcomes following hyperopic LASIK.

Authors:  George Fatseas; Fiona Stapleton; Patrick Versace
Journal:  PLoS One       Date:  2017-02-02       Impact factor: 3.240

7.  Corneal power changes with Scheimpflug rotating camera after hyperopic LASIK.

Authors:  Woong-Joo Whang; Young-Sik Yoo; Choun-Ki Joo
Journal:  Medicine (Baltimore)       Date:  2018-12       Impact factor: 1.817

  7 in total

北京卡尤迪生物科技股份有限公司 © 2022-2023.