Literature DB >> 12231279

Is there a haemodynamic advantage associated with cuffed arterial anastomoses?

J S Cole1, J K Watterson, M J G O'Reilly.   

Abstract

The development of intimal hyperplasia at arterial bypass graft anastomoses is a major factor responsible for graft failure. A revised surgical technique, involving the incorporation of a small section of vein (vein cuff) into the distal anastomosis of PTFE grafts, results in an altered distribution of intimal hyperplasia and improved graft patency rates, especially for below-knee grafts. Numerical simulations have been conducted under physiological conditions to identify the flow behaviour in a typical cuffed bypass model and to determine whether the improved performance of the cuffed system can be accounted for by haemodynamic factors. The flow patterns at the cuffed anastomosis are significantly different to those at the conventional end-to-side anastomosis. In the former case, the flow is characterised by an expansive, low momentum recirculation within the cuff. Separation occurs at the graft heel, and at the cuff toe as the blood enters the recipient artery. Wall shear stresses in the vicinity of the cuff heel are low, but high shear stresses and large spatial gradients in the shearing force act on the artery floor during systole. In contrast, a less disturbed flow prevails and the floor shear stress distribution is less adverse in the conventional model. In conclusion, aspects of the anastomotic haemodynamics are worsened when the cuff is employed. The benefits associated with the cuffed grafts may be related primarily to the presence of venous material at the anastomosis. Therefore, caution is advised with regard to the use of PTFE grafts, pre-shaped to resemble a cuffed geometry.

Entities:  

Mesh:

Year:  2002        PMID: 12231279     DOI: 10.1016/s0021-9290(02)00174-4

Source DB:  PubMed          Journal:  J Biomech        ISSN: 0021-9290            Impact factor:   2.712


  2 in total

1.  Impact of in vivo ranges of the variances in the flow velocity waveforms and flow split ratio on the hemodynamic effects of the anastomotic cuff at distal end-to-side anastomosis.

Authors:  Hiroshi Mitsuoka; Siro Kitamura; Kunio Kuwahara; Naoki Unno
Journal:  Surg Today       Date:  2006       Impact factor: 2.549

Review 2.  Neointimal hyperplasia associated with synthetic hemodialysis grafts.

Authors:  Li Li; Christi M Terry; Yan-Ting E Shiu; Alfred K Cheung
Journal:  Kidney Int       Date:  2008-07-30       Impact factor: 10.612

  2 in total

北京卡尤迪生物科技股份有限公司 © 2022-2023.