Literature DB >> 12230091

Evaluation of a commercial PET tomograph-based system for the quantitative assessment of rCBF, rOEF and rCMRO2 by using sequential administration of 15O-labeled compounds.

Miho Shidahara1, Hiroshi Watabe, Kyeong Min Kim, Hisashi Oka, Masayoshi Sago, Takuya Hayashi, Yoshinori Miyake, Yoshio Ishida, Kohei Hayashida, Takashi Nakamura, Hidehiro Iida.   

Abstract

The purpose of this study was to develop a reliable and practical strategy that generates quantitative CBF and OEF maps accurately from PET data sets obtained with 15O-tracers. Sequential sinogram data sets were acquired after the administration of 15O-tracers, and combined single-frame images were obtained. The delay time between sampled input function and the brain was estimated from the H2(15)O study with the whole brain and the arterial time-activity curves (TACs). The whole-brain TACs were obtained from the reconstructed images (image-base method) and the sinogram data (sinogram-base method). Six methods were also evaluated for the dead-time and decay correction procedures in the process of generating a single-frame image from the dynamic sinogram. The estimated delay values were similar with both the sinogram-based and image-based methods. A lumped correction factor to a previously added single-frame sinogram caused an underestimation of CBF, OEF and CMRO2 by 16% at maximum, as compared with the correction procedure for a short sinogram. This suggested the need for a dynamic acquisition of a sinogram with a short interval. The proposed strategy provided an accurate quantification of CBF and OEF by PET with 15O-tracers.

Entities:  

Mesh:

Substances:

Year:  2002        PMID: 12230091     DOI: 10.1007/BF02988616

Source DB:  PubMed          Journal:  Ann Nucl Med        ISSN: 0914-7187            Impact factor:   2.668


  10 in total

1.  A positron-probe system for arterial input function quantification for positron emission tomography in humans.

Authors:  Kihak Lee; Peter T Fox; Jack L Lancaster; Paul A Jerabek
Journal:  Rev Sci Instrum       Date:  2008-06       Impact factor: 1.523

2.  Effects of a novel tungsten-impregnated rubber neck shield on the quality of cerebral images acquired using 15O-labeled gas.

Authors:  Kei Wagatsuma; Keiichi Oda; Kenta Miwa; Motoki Inaji; Muneyuki Sakata; Jun Toyohara; Kiichi Ishiwata; Masayuki Sasaki; Kenji Ishii
Journal:  Radiol Phys Technol       Date:  2017-08-19

3.  Bayesian Estimation of CBF Measured by DSC-MRI in Patients with Moyamoya Disease: Comparison with 15O-Gas PET and Singular Value Decomposition.

Authors:  S Hara; Y Tanaka; S Hayashi; M Inaji; T Maehara; M Hori; S Aoki; K Ishii; T Nariai
Journal:  AJNR Am J Neuroradiol       Date:  2019-10-10       Impact factor: 3.825

4.  Mapping functional connectivity based on synchronized CMRO2 fluctuations during the resting state.

Authors:  Changwei W Wu; Hong Gu; Hanbing Lu; Elliot A Stein; Jyh-Horng Chen; Yihong Yang
Journal:  Neuroimage       Date:  2009-04-15       Impact factor: 6.556

5.  Quantification of regional myocardial oxygen metabolism in normal pigs using positron emission tomography with injectable (15)O-O (2).

Authors:  Takashi Temma; Hidehiro Iida; Takuya Hayashi; Noboru Teramoto; Youichiro Ohta; Nobuyuki Kudomi; Hiroshi Watabe; Hideo Saji; Yasuhiro Magata
Journal:  Eur J Nucl Med Mol Imaging       Date:  2009-09-04       Impact factor: 9.236

6.  Rapid quantitative CBF and CMRO(2) measurements from a single PET scan with sequential administration of dual (15)O-labeled tracers.

Authors:  Nobuyuki Kudomi; Yoshiyuki Hirano; Kazuhiro Koshino; Takuya Hayashi; Hiroshi Watabe; Kazuhito Fukushima; Hiroshi Moriwaki; Noboru Teramoto; Koji Iihara; Hidehiro Iida
Journal:  J Cereb Blood Flow Metab       Date:  2012-12-12       Impact factor: 6.200

7.  Intravoxel incoherent motion perfusion in patients with Moyamoya disease: comparison with 15O-gas positron emission tomography.

Authors:  Shoko Hara; Masaaki Hori; Ryo Ueda; Akifumi Hagiwara; Shihori Hayashi; Motoki Inaji; Yoji Tanaka; Taketoshi Maehara; Kenji Ishii; Shigeki Aoki; Tadashi Nariai
Journal:  Acta Radiol Open       Date:  2019-05-23

Review 8.  Quantification of brain oxygen extraction and metabolism with [15O]-gas PET: A technical review in the era of PET/MRI.

Authors:  Audrey P Fan; Hongyu An; Farshad Moradi; Jarrett Rosenberg; Yosuke Ishii; Tadashi Nariai; Hidehiko Okazawa; Greg Zaharchuk
Journal:  Neuroimage       Date:  2020-07-04       Impact factor: 6.556

9.  Imaging of the appearance time of cerebral blood using [15O]H2O PET for the computation of correct CBF.

Authors:  Nobuyuki Kudomi; Yukito Maeda; Yasuhiro Sasakawa; Toshihide Monden; Yuka Yamamoto; Nobuyuki Kawai; Hidehiro Iida; Yoshihiro Nishiyama
Journal:  EJNMMI Res       Date:  2013-05-23       Impact factor: 3.138

10.  Applicability of emission-based attenuation map for rapid CBF, OEF, and CMRO2 measurements using gaseous (15)O-labeled compounds.

Authors:  Yukito Maeda; Nobuyuki Kudomi; Yasuhiro Sasakawa; Toshihide Monden; Koji Kato; Yuka Yamamoto; Nobuyuki Kawai; Yoshihiro Nishiyama
Journal:  EJNMMI Phys       Date:  2015-05-30
  10 in total

北京卡尤迪生物科技股份有限公司 © 2022-2023.