Pseudoaneurysm of the pulmonary artery (PA) induced by Swan-Ganz catheter injury is an important complication with high mortality. We report a case of PA pseudoaneurysm treated by PA repair. A 52-year-old woman developing infiltrate in the right lung field in chest radiography after a second mitral valve replacement was diagnosed with PA pseudoaneurysm confirmed by contrast-enhanced computed tomography and pulmonary angiography. The cause was considered Swan-Ganz catheter injury. The patient was carefully observed because there was no evidence of bronchial hemorrhage. The perforation was closed and the cavity plicated under extracorporeal circulation to avoid delayed rupture of the pseudoaneurysm when she underwent a third mitral valve replacement.

Entities:  

Mesh:

Year:  2002        PMID: 12229220     DOI: 10.1007/BF03032630

Source DB:  PubMed          Journal:  Jpn J Thorac Cardiovasc Surg        ISSN: 1344-4964


  5 in total

Review 1.  Flow-directed, pulmonary artery catheter-induced pseudoaneurysm: urgent diagnosis and endovascular obliteration.

Authors:  O C Kirton; A J Varon; R P Henry; J M Civetta
Journal:  Crit Care Med       Date:  1992-08       Impact factor: 7.598

Review 2.  Catheter-induced pulmonary artery false aneurysm and rupture: case report and review.

Authors:  L G DeLima; J E Wynands; M E Bourke; V M Walley
Journal:  J Cardiothorac Vasc Anesth       Date:  1994-02       Impact factor: 2.628

Review 3.  Swan-Ganz catheter-induced pulmonary artery pseudoaneurysm: a case of complete resolution without intervention.

Authors:  C K You; G S Whatley
Journal:  Can J Surg       Date:  1994-10       Impact factor: 2.089

4.  Pulmonary artery rupture associated with the Swan-Ganz catheter.

Authors:  T J Kearney; M M Shabot
Journal:  Chest       Date:  1995-11       Impact factor: 9.410

5.  Pulmonary artery false aneurysms secondary to Swan-Ganz pulmonary artery catheters.

Authors:  J D Dieden; L A Friloux; J W Renner
Journal:  AJR Am J Roentgenol       Date:  1987-11       Impact factor: 3.959

  5 in total
  2 in total

1.  Endovascular treatment of PA pseudoaneurysm caused by Swan-Ganz catheter.

Authors:  Piotr N Rudziński; Marcin Demkow; Ilona Michałowska; Elżbieta Abramczuk; Piotr Szymański
Journal:  Postepy Kardiol Interwencyjnej       Date:  2014-03-23       Impact factor: 1.426

2.  Pulmonary artery rupture as a complication of Swan-Ganz catheter application. Diagnosis and endovascular treatment: a single centre's experience.

Authors:  Piotr N Rudziński; Jan Henzel; Zofia Dzielińska; Barbara M Lubiszewska; Ilona Michałowska; Piotr Szymański; Radosław Pracoń; Tomasz Hryniewiecki; Marcin Demkow
Journal:  Postepy Kardiol Interwencyjnej       Date:  2016-05-11       Impact factor: 1.426

  2 in total