Literature DB >> 12227622

Instrumented rod rotator system for spinal surgery.

E Lou1, D L Hill, J V Raso, M J Moreau, J K Mahood.   

Abstract

An electronically instrumented rod rotator has been developed to monitor forces and moments applied by surgeons during the derotation manoeuver to correct spinal curvature. This instrumented rod rotator consisted of an inclinometer and two pairs of strain gauges, with all the support circuitry. The strain gauge and the inclinometer data were sampled with a data-acquisition system, and the results were displayed in real time. The device was calibrated in the laboratory and used on seven subjects. The precision of the load measurement of this device was +/- 5 N in the range of 5-65N. The distance between the middle of the rod rotator handle to the rod position was 0.21 m. The maximum loads applied by the surgeon during seven surgeries were from 22 to 57N, with a torque (force x distance) from 4.6 to 12 Nm.

Mesh:

Year:  2002        PMID: 12227622     DOI: 10.1007/BF02345068

Source DB:  PubMed          Journal:  Med Biol Eng Comput        ISSN: 0140-0118            Impact factor:   2.602


  5 in total

Review 1.  Application technique of Cotrel-Dubousset instrumentation for scoliosis deformities.

Authors:  J Dubousset; Y Cotrel
Journal:  Clin Orthop Relat Res       Date:  1991-03       Impact factor: 4.176

2.  Force measurements during operative correction of spinal deformities.

Authors:  G G McBride; H K Dunn; A U Daniels
Journal:  Biomed Sci Instrum       Date:  1979 Apr 23-25

3.  Telemetry recordings of forces in the Harrington distraction rod: a method for increasing safety in the operative treatment of scoliosis patients.

Authors:  G Elfström; A Nachemson
Journal:  Clin Orthop Relat Res       Date:  1973-06       Impact factor: 4.176

4.  The prediction of curve progression in untreated idiopathic scoliosis during growth.

Authors:  J E Lonstein; J M Carlson
Journal:  J Bone Joint Surg Am       Date:  1984-09       Impact factor: 5.284

5.  Three-dimensional simulations of the scoliosis derotation maneuver with Cotrel-Dubousset instrumentation.

Authors:  M Gardner-Morse; I A Stokes
Journal:  J Biomech       Date:  1994-02       Impact factor: 2.712

  5 in total
  1 in total

1.  The importance of curve severity, type and instrumentation strategy in the surgical correction of adolescent idiopathic scoliosis: an in silico clinical trial on 64 cases.

Authors:  Fabio Galbusera; Andrea Cina; Matteo Panico; Tito Bassani
Journal:  Sci Rep       Date:  2021-01-19       Impact factor: 4.379

  1 in total