Literature DB >> 12225713

Detection of coronary restenosis after coronary angioplasty by contrast-enhanced transthoracic echocardiographic Doppler assessment of coronary flow velocity reserve.

Massimo Ruscazio1, Roberta Montisci, Paolo Colonna, Carlo Caiati, Lijun Chen, Giorgio Lai, Mauro Cadeddu, Raimondo Pirisi, Sabino Iliceto.   

Abstract

OBJECTIVES: This study sought to evaluate the diagnostic potential of contrast-enhanced transthoracic echocardiography (CE-TTE) during adenosine infusion, a noninvasive method for evaluating coronary flow reserve (CFR), in detecting restenosis after successful percutaneous transluminal coronary angioplasty (PTCA).
BACKGROUND: Restenosis is the most important limitation of PTCA, and CFR can be impaired in patients with angiographically documented significant coronary stenosis.
METHODS: We performed 6 +/- 2 months of follow-up of 53 patients after successful elective PTCA in the left anterior descending coronary artery (LAD). Coronary angiography was performed at the end of the planned follow-up period or even before, if clinically indicated. Thus, of the 53 patients, a total of 63 angiographic studies were performed; CE-TTE assessment of CFR was achieved before each of the 63 angiographic studies.
RESULTS: Coronary angiography revealed the presence of restenosis (defined as >50% stenosis at a previous PTCA site) in 32 angiographic examinations (group A) and no coronary restenosis in the remaining 31 examinations (group B). Coronary flow reserve was significantly reduced in group A compared with group B (1.65 +/- 0.5 vs. 3.17 +/- 0.8, p < or = 0.001). A noninvasive CFR value < or = 2 was 93% specific and 78% sensitive for detecting significant restenosis, with positive and negative diagnostic accuracies of 92% and 80%, respectively.
CONCLUSIONS: Noninvasive CFR assessment by CE-TTE is an accurate method of monitoring significant restenosis in the LAD when following up patients submitted to elective PTCA.

Entities:  

Mesh:

Year:  2002        PMID: 12225713     DOI: 10.1016/s0735-1097(02)02055-7

Source DB:  PubMed          Journal:  J Am Coll Cardiol        ISSN: 0735-1097            Impact factor:   24.094


  9 in total

1.  Possible further reduction in coronary flow velocity reserve in angina pectoris patients after oral glucose loading.

Authors:  Hidetoshi Yoshitani; Masaaki Takeuchi; Yutaka Otsuji; Takashi Akasaka; Kiyoshi Yoshida
Journal:  J Echocardiogr       Date:  2013-01-22

Review 2.  Coronary Flow Velocity Reserve Assessment with Transthoracic Doppler Echocardiography.

Authors:  Iana Simova
Journal:  Eur Cardiol       Date:  2015-07

3.  Effect of one or more co-morbid conditions on diagnostic accuracy of coronary flow velocity reserve for detecting significant left anterior descending coronary stenosis.

Authors:  H Yoshitani; M Takeuchi; K Sakamoto; T Akasaka; K Yoshida; J Yoshikawa
Journal:  Heart       Date:  2005-10       Impact factor: 5.994

Review 4.  Coronary flow reserve in stress-echo lab. From pathophysiologic toy to diagnostic tool.

Authors:  Fausto Rigo
Journal:  Cardiovasc Ultrasound       Date:  2005-03-25       Impact factor: 2.062

5.  Feasibility of 3D4D echocardiography for the detection of colour-coded flow in the left anterior descending artery.

Authors:  Stephan Stoebe; Dietrich Pfeiffer; Andreas Hagendorff
Journal:  Echo Res Pract       Date:  2014-07-23

Review 6.  Status and potential clinical value of a transthoracic evaluation of the coronary arteries.

Authors:  Fabien Labombarda; Samuela Castelnuovo; Dionysis Goularas; Cesare R Sirtori
Journal:  Cardiovasc Ultrasound       Date:  2016-01-19       Impact factor: 2.062

7.  Distal left circumflex coronary artery flow reserve recorded by transthoracic Doppler echocardiography: a comparison with Doppler-wire.

Authors:  Antonio Auriti; Christian Pristipino; Cinzia Cianfrocca; Antonino Granatelli; Vincenzo Guido; Francesco Pelliccia; Salvatore Greco; Giuseppe Richichi; Massimo Santini
Journal:  Cardiovasc Ultrasound       Date:  2007-06-16       Impact factor: 2.062

Review 8.  Transthoracic Doppler echocardiography - noninvasive diagnostic window for coronary flow reserve assessment.

Authors:  Paweł Petkow Dimitrow
Journal:  Cardiovasc Ultrasound       Date:  2003-04-11       Impact factor: 2.062

Review 9.  Imaging of all three coronary arteries by transthoracic echocardiography. An illustrated guide.

Authors:  Marek Krzanowski; Wojciech Bodzoń; Pawel Petkow Dimitrow
Journal:  Cardiovasc Ultrasound       Date:  2003-11-17       Impact factor: 2.062

  9 in total

北京卡尤迪生物科技股份有限公司 © 2022-2023.