Literature DB >> 12223297

Detection of Escherichia coli O157:H7 using immunomagnetic separation and absorbance measurement.

Yongcheng Liu1, Yanbin Li.   

Abstract

An assay system for detection of Escherichia coli O157:H7 was developed based on immunomagnetic separation of the target pathogen from samples and absorbance measurement of p-nitrophenol at 400 nm from p-nitrophenyl phosphate hydrolysis by alkaline phosphatase (EC 3.1.3.1) on the "sandwich" structure complexes (antibodies coated onto micromagnetic beads--E. coli O157:H7-antibodies conjugated with the enzyme) formed on the microbead surface. The effects of immunoreaction time, phosphate buffer concentration, pH and temperature on the immunomagnetic separation of E. coli O157:H7 from samples were determined and the conditions used for the separation were 1-h reaction time, 1.0 x 10(-2) M PBS, pH 8.0 and 33 degrees C in this system. The effects of MgCl(2) concentration, Tris buffer concentration, pH and temperature on the activity of alkaline phosphatase conjugated on the immuno-"sandwich" structure complexes were investigated after immunomagnetic separation of the target pathogen and the conditions used for the enzymatic amplification were 1.0 x 10(-4) M MgCl(2), 1.0 M Tris buffer, pH 8.0, 28 degrees C and 30-min reaction time during the assay. The selectivity of the system was examined and no interference from the other pathogens including Salmonella typhimurium, Campylobacter jejuni and Listeria monocytogenes was observed. Its working range was from 3.2 x 10(2) to 3.2 x 10(4) CFU/ml, and the relative standard deviation was 2.5-9.9%. The total detection time was less than 2 h. Copyright 2002 Elsevier Science B.V.

Entities:  

Mesh:

Substances:

Year:  2002        PMID: 12223297     DOI: 10.1016/s0167-7012(02)00107-0

Source DB:  PubMed          Journal:  J Microbiol Methods        ISSN: 0167-7012            Impact factor:   2.363


  3 in total

1.  Matrix-assisted laser desorption ionization-time of flight mass spectrometry for the discrimination of food-borne microorganisms.

Authors:  Maria Fiorella Mazzeo; Alida Sorrentino; Marcello Gaita; Giuseppina Cacace; Michele Di Stasio; Angelo Facchiano; Giuseppe Comi; Antonio Malorni; Rosa Anna Siciliano
Journal:  Appl Environ Microbiol       Date:  2006-02       Impact factor: 4.792

2.  Heat and Chemical Treatments Affect the Viability, Morphology, and Physiology of Staphylococcus aureus and Its Subsequent Antibody Labeling for Flow Cytometric Analysis.

Authors:  Deirdre Kennedy; Ultan P Cronin; Anna Piterina; Martin G Wilkinson
Journal:  Appl Environ Microbiol       Date:  2019-08-14       Impact factor: 4.792

3.  Detection of pathogens using luminescent CdSe/ZnS dendron nanocrystals and a porous membrane immunofilter.

Authors:  Yongcheng Liu; Robert Brandon; Michael Cate; Xiaogang Peng; Robert Stony; Michael Johnson
Journal:  Anal Chem       Date:  2007-10-17       Impact factor: 6.986

  3 in total

北京卡尤迪生物科技股份有限公司 © 2022-2023.