Literature DB >> 12221702

Oxidation-induced dynamic changes in morphology reflected on freeze-fractured surface of gamma-irradiated ultra-high molecular weight polyethylene components.

Eiichiro Watanabe1, Masahiko Suzuki, Kazuya Nagata, Toshiaki Kaneeda, Yoshitada Harada, Masahiro Utsumi, Akiko Mori, Hideshige Moriya.   

Abstract

Oxidative degradation of ultra-high molecular weight polyethylene (UHMWPE) attributed to sterilization by gamma-radiation in the presence of air has been cited as one of the major causes of premature wear in total joint arthroplasty. For example, in retrieved UHMWPE tibial bearings, not only adhesive and abrasive wear, but also fatigue wear characterized by delamination and fracture is frequently observed. In this study, we examined the effects of gamma radiation on the microstructural morphology of UHMWPE tibial bearings, and propose a severe fatigue wear mechanism. Scanning electron microscopic observations were conducted on freeze-fractured surface of retrieved UHMWPE components that had been sterilized with gamma radiation in air before implantation, unused components that had been stored on the shelf for several years (5-11) after sterilization, and disc specimens given an accelerated aging protocol after gamma radiation. Scanning electron microscopic observations showed that the freeze-fractured surface of these components had a double layer, which was bordered below the surface. A closer observation of the subsurface layer below the border revealed an extremely rough and porous honeycomb-like structure. Fourier transform infrared analysis demonstrated that the honeycomb-like region in the subsurface had a high oxidation level. The internal morphology of oxidized UHMWPE was classified into four categories based on the level of the oxidation. According to these results, the morphological changes with oxidative degradation of gamma-irradiated UHMWPEs in the presence of air could consistently be explained as the result of major chemical and physical changes such as increased crystallinity, elevated density, and reduced mechanical strength. We relate the morphological changes caused by oxidative degradation in the subsurface to the location of the origin of fatigue wear in total knee joints. Copyright 2002 Wiley Periodicals, Inc.

Entities:  

Mesh:

Substances:

Year:  2002        PMID: 12221702     DOI: 10.1002/jbm.10357

Source DB:  PubMed          Journal:  J Biomed Mater Res        ISSN: 0021-9304


  2 in total

1.  Relationship between apatite-forming ability and mechanical properties of bioactive PMMA-based bone cement modified with calcium salts and alkoxysilane.

Authors:  Atsushi Sugino; Toshiki Miyazaki; Giichiro Kawachi; Koichi Kikuta; Chikara Ohtsuki
Journal:  J Mater Sci Mater Med       Date:  2007-10-04       Impact factor: 3.896

2.  A comparative study of flat surface design and medial pivot design in posterior cruciate-retaining total knee arthroplasty: a matched pair cohort study of two years.

Authors:  Junichi Nakamura; Takaki Inoue; Toru Suguro; Masahiko Suzuki; Takahisa Sasho; Shigeo Hagiwara; Ryuichiro Akagi; Sumihisa Orita; Kazuhide Inage; Tsutomu Akazawa; Seiji Ohtori
Journal:  BMC Musculoskelet Disord       Date:  2018-07-18       Impact factor: 2.362

  2 in total

北京卡尤迪生物科技股份有限公司 © 2022-2023.