OBJECTIVE: Data on the accuracy of transthoracic echocardiographic (TTE) analysis of coronary flow reserve are scarce. We compared coronary flow reserve measurements assessed using TTE with those achieved using the gold standard of intracoronary Doppler. METHODS: Twenty-one patients admitted for elective coronary angioplasty to the circumflex or left anterior descending (LAD) coronary artery underwent TTE immediately before angioplasty, both at rest and during intravenous administration of adenosine 140 microg/kg/min. Transthoracic images of distal LAD coronary diameter and coronary flow were obtained in 14 patients (66%). These patients then underwent intracoronary Doppler analysis of coronary flow reserve in the distal LAD coronary artery. In 1 patient with a proximal LAD artery lesion, the narrowing could not be crossed with the Doppler guidewire. Paired data on coronary flow reserve were therefore available in 13 patients. RESULTS: Patients were aged 61.7 +/- 8.3 years. Ten were men. Body mass index was 26.3 +/- 4.6 kg/m(2). Resting distal LAD artery blood flow was 18.4 +/- 9.0 mL/min assessed by TTE versus 17.6 +/- 8.1 mL/min by intracoronary Doppler. Hyperemic flow was 36.3 +/- 23.4 versus 33.1 +/- 19.2 mL/min, respectively. Coronary flow reserve was therefore 1.89 +/- 0.66 by TTE compared with 1.83 +/- 0.62 by intracoronary Doppler. Limits of agreement for coronary flow reserve were -0.28 to +0.44, well within boundaries of clinical acceptability. CONCLUSION: Transthoracic echocardiography is capable of providing accurate data on coronary flow reserve in the distal LAD coronary artery. As a truly noninvasive modality, this technique offers advantages over traditional invasive procedures.
OBJECTIVE: Data on the accuracy of transthoracic echocardiographic (TTE) analysis of coronary flow reserve are scarce. We compared coronary flow reserve measurements assessed using TTE with those achieved using the gold standard of intracoronary Doppler. METHODS: Twenty-one patients admitted for elective coronary angioplasty to the circumflex or left anterior descending (LAD) coronary artery underwent TTE immediately before angioplasty, both at rest and during intravenous administration of adenosine 140 microg/kg/min. Transthoracic images of distal LAD coronary diameter and coronary flow were obtained in 14 patients (66%). These patients then underwent intracoronary Doppler analysis of coronary flow reserve in the distal LAD coronary artery. In 1 patient with a proximal LAD artery lesion, the narrowing could not be crossed with the Doppler guidewire. Paired data on coronary flow reserve were therefore available in 13 patients. RESULTS:Patients were aged 61.7 +/- 8.3 years. Ten were men. Body mass index was 26.3 +/- 4.6 kg/m(2). Resting distal LAD artery blood flow was 18.4 +/- 9.0 mL/min assessed by TTE versus 17.6 +/- 8.1 mL/min by intracoronary Doppler. Hyperemic flow was 36.3 +/- 23.4 versus 33.1 +/- 19.2 mL/min, respectively. Coronary flow reserve was therefore 1.89 +/- 0.66 by TTE compared with 1.83 +/- 0.62 by intracoronary Doppler. Limits of agreement for coronary flow reserve were -0.28 to +0.44, well within boundaries of clinical acceptability. CONCLUSION: Transthoracic echocardiography is capable of providing accurate data on coronary flow reserve in the distal LAD coronary artery. As a truly noninvasive modality, this technique offers advantages over traditional invasive procedures.
Authors: Naja Dam Mygind; Marie Mide Michelsen; Adam Pena; Abbas Ali Qayyum; Daria Frestad; Thomas Emil Christensen; Adam Ali Ghotbi; Nynne Dose; Rebekka Faber; Niels Vejlstrup; Philip Hasbak; Andreas Kjaer; Eva Prescott; Jens Kastrup Journal: J Cardiovasc Magn Reson Date: 2016-11-04 Impact factor: 5.364
Authors: Kira Bang Bove; Marie M Michelsen; Jakob Schroder; Hannah Elena Suhrs; Daria F Bechsgaard; Naja Dam Mygind; Ahmed Aziz; Jens Kastrup; Ida Gustafsson; Eva Prescott Journal: Open Heart Date: 2021-01
Authors: Rasmus Huan Olsen; Lene Rørholm Pedersen; Martin Snoer; Thomas Emil Christensen; Adam Ali Ghotbi; Philip Hasbak; Andreas Kjaer; Steen B Haugaard; Eva Prescott Journal: Cardiovasc Ultrasound Date: 2016-06-07 Impact factor: 2.062
Authors: Kira Bang Bove; Malin Nilsson; Lene Rørholm Pedersen; Nicolai Mikkelsen; Hannah Elena Suhrs; Arne Astrup; Eva Prescott Journal: PLoS One Date: 2020-11-05 Impact factor: 3.240