Correlation between measured inferior vena cava diameter and right atrial pressure depends on the echocardiographic method used in patients who are mechanically ventilated.

Karim Bendjelid1, Jacques-A Romand, Bernhard Walder, Peter M Suter, Gerard Fournier.   

Abstract

In patients who are mechanically ventilated, the correlation between inferior vena cava diameter (IVCD) measurements and mean right atrial pressure (RAP) varies in the literature. The purpose of this study was to test if the correlation between IVCD and RAP measurement in patients who are critically ill depends on the transthoracic echocardiography (TTE) methodology used. Twenty patients who were critically ill, sedated, and required respiratory support were prospectively studied by TTE during mechanical ventilation in a controlled mode. The TTE measures of IVCD were made, using methods previously cited. First, IVCD was measured at end-expiration and end-diastole, with ECG synchronization, using the M-mode, on short-axis view 2 cm below the right atrium. Second, IVCD was assessed at end-expiration, without ECG synchronization, using the 2-dimensional long-axis view at the same location. RAP was measured simultaneously by using a central venous catheter positioned in the superior vena cava. All measurements were taken in the supine position. IVCD at end-expiration and end-diastole, with ECG synchronization, using the M-mode, and IVCD at end-expiration, without ECG synchronization, using the 2-dimensional long-axis view, correlate linearly with RAP (0.81, P <.0001 and 0.71, P =.0004). Mean bias between the 2 TTE methods (Bland-Altman analysis) was 1.6 mm (SD +/- 2.03 mm). In conclusion, this study confirms that variation of correlation between TTE IVCD measurement and RAP depends on the ultrasonographic methodology used and the timing of measurement during the cardiac cycle. IVCD at end-expiration and end-diastole, with ECG synchronization, using the M-mode (IVCD-MM) correlates more satisfactory with RAP than with IVCD at end-expiration, without ECG synchronization, using the 2-dimensional long-axis view, in patients during mechanical ventilation.

Entities:  

Mesh:

Year:  2002        PMID: 12221411     DOI: 10.1067/mje.2002.120701

Source DB:  PubMed          Journal:  J Am Soc Echocardiogr        ISSN: 0894-7317            Impact factor:   5.251


  9 in total

1.  Predicting fluid responsiveness: should we adapt the scale to measure the central venous pressure swing?

Authors:  Karim Bendjelid
Journal:  Intensive Care Med       Date:  2004-06-09       Impact factor: 17.440

2.  Can non-invasive ventilation modify central venous pressure? Comparison between invasive measurement and ultrasonographic evaluation.

Authors:  Maurizio Zanobetti; Alessio Prota; Alessandro Coppa; Laura Giordano; Sofia Bigiarini; Peiman Nazerian; Francesca Innocenti; Alberto Conti; Federica Trausi; Simone Vanni; Giuseppe Pepe; Riccardo Pini
Journal:  Intern Emerg Med       Date:  2016-11-22       Impact factor: 3.397

3.  Prognostic significance of dilated inferior vena cava in advanced decompensated heart failure.

Authors:  Hsin-Fu Lee; Lung-An Hsu; Chi-Jen Chang; Yi-Hsin Chan; Chun-Li Wang; Wan-Jing Ho; Pao-Hsien Chu
Journal:  Int J Cardiovasc Imaging       Date:  2014-06-18       Impact factor: 2.357

4.  Echocardiographic Assessment of Right Atrial Pressure in a Pediatric and Young Adult Population.

Authors:  Bhawna Arya; Diane Kerstein; Cheng-Shiun Leu; Denise Hayes; Warren A Zuckerman; Usha Krishnan; Wyman W Lai
Journal:  Pediatr Cardiol       Date:  2015-12-14       Impact factor: 1.655

5.  Early markers of right heart involvement in regular smokers by Pocket Size Imaging Device.

Authors:  Vincenzo Schiano-Lomoriello; Roberta Esposito; Ciro Santoro; Giovanni de Simone; Maurizio Galderisi
Journal:  Cardiovasc Ultrasound       Date:  2015-07-23       Impact factor: 2.062

6.  Can Nephrologists Use Ultrasound to Evaluate the Inferior Vena Cava? A Cross-Sectional Study of the Agreement between a Nephrologist and a Cardiologist.

Authors:  José Muniz Pazeli; Daniel Fagundes Vidigal; Tarcísio Cestari Grossi; Natália Maria Silva Fernandes; Fernando Colugnati; Rogério Baumgratz de Paula; Hélady Sanders-Pinheiro
Journal:  Nephron Extra       Date:  2014-04-30

Review 7.  Respiratory maneuvers in echocardiography: a review of clinical applications.

Authors:  Carmen Ginghina; Carmen C Beladan; Madalina Iancu; Andreea Calin; Bogdan A Popescu
Journal:  Cardiovasc Ultrasound       Date:  2009-08-26       Impact factor: 2.062

8.  Does inferior vena cava respiratory variability predict fluid responsiveness in spontaneously breathing patients?

Authors:  Norair Airapetian; Julien Maizel; Ola Alyamani; Yazine Mahjoub; Emmanuel Lorne; Melanie Levrard; Nacim Ammenouche; Aziz Seydi; François Tinturier; Eric Lobjoie; Hervé Dupont; Michel Slama
Journal:  Crit Care       Date:  2015-11-13       Impact factor: 9.097

9.  Measurement of Central Venous Pressure Using Ultrasound in Emergency Department.

Authors:  Ahmad Abbasian; Hamideh Feiz Disfani; Mohammad Afzalimoghaddam; Mohammad Taghi Talebian; Babak Masoumi; Mohammad Nasr-Esfahani
Journal:  Iran Red Crescent Med J       Date:  2015-12-24       Impact factor: 0.611

  9 in total

北京卡尤迪生物科技股份有限公司 © 2022-2023.