Literature DB >> 12220342

Effect of HEMA on bonding of Er:YAG laser-irradiated bovine dentine and 4-META/MMA-TBB resin.

A Kameyama1, E Kawada, T Amagai, M Takizawa, Y Oda, Y Hirai.   

Abstract

The purpose of this study was to evaluate the priming effect of 2-hydroxyethylmetaclirate (HEMA) following acid treatment on resin bonding to prototype Er:YAG laser-irradiated dentine. Extracted bovine dentine following laser irradiation was acid treated by aqueous solution of 10% citric acid (10-0) or 10% citric acid/3% ferric chloride (10-3), and additionally treated with 35% HEMA. Pre-treated dentines were bonded to the polymethyl-methacrylate (PMMA) rod with 4-META/MMA-TBB resin (Super Bond C & B) and miniaturized dumbbell-shaped bonded specimens were prepared. These specimens profiled for tensile bond testing and fractured surfaces were observed by scanning electron microscopy (SEM). Cross-sections of resin-dentine interface were also examined. The HEMA treatment following acid conditioned by 10-3 or 10-0 for both laser-irradiated and non-irradiated dentines was significantly higher than that without HEMA treatment. SEM view of a fractured specimen showed some cohesive failure in cured resin, but almost all of the fractured surface shows boundary failure between the penetrated resin and underlying dentine. A cross-sectional view of the interface showed a very thick hybrid layer between the hybridized dentine and underlying dentine. It was concluded that HEMA treatment following acid conditioning provided a slightly higher bond strength for both the Er:YAG laser-irradiated and non-irradiated dentines. However, the bond strength of Er:YAG laser irradiated dentine was significantly lower than that of the non-irradiated dentine.

Entities:  

Mesh:

Substances:

Year:  2002        PMID: 12220342     DOI: 10.1046/j.1365-2842.2002.00954.x

Source DB:  PubMed          Journal:  J Oral Rehabil        ISSN: 0305-182X            Impact factor:   3.837


  3 in total

1.  Effect of pretreatment on Er:YAG laser-irradiated dentin.

Authors:  Min-le Chen; Jiang-feng Ding; Yong-jiang He; Yi Chen; Qian-zhou Jiang
Journal:  Lasers Med Sci       Date:  2013-08-16       Impact factor: 3.161

2.  Comparison of tensile bond strengths of four one-bottle self-etching adhesive systems with Er:YAG laser-irradiated dentin.

Authors:  Qianzhou Jiang; Minle Chen; Jiangfeng Ding
Journal:  Mol Biol Rep       Date:  2013-11-05       Impact factor: 2.316

3.  A three-dimensional evaluation of microleakage of class V cavities prepared by the very short pulse mode of the erbium:yttrium-aluminium-garnet laser.

Authors:  Silvana Jukić Krmek; Ivana Bogdan; Paris Simeon; Goranka Prpić Mehicić; Davor Katanec; Ivica Anić
Journal:  Lasers Med Sci       Date:  2009-07-11       Impact factor: 3.161