Literature DB >> 12218821

Benign tracheobronchial stenoses: changes in short-term and long-term pulmonary function testing after expandable metallic stent placement.

Michael B Gotway1, Jeffrey A Golden, Jeanne M LaBerge, W Richard Webb, Gautham P Reddy, Mark W Wilson, Robert K Kerlan, Roy L Gordon.   

Abstract

PURPOSE: To determine the short- and long-term improvement in airflow dynamics in patients undergoing tracheobronchial stent placement for benign airway stenoses.
METHODS: Twenty-two patients underwent 34 tracheal and/or bronchial stent placement procedures for benign airway stenoses and had the results of pulmonary function tests available. Stent placement indications included bronchomalacia after lung transplantation (n = 11), postintubation stenoses (n = 6), relapsing polychondritis (n = 2), and 1 each of tracheomalacia, tracheal compression, and histoplasmosis. Six patients underwent more than one stent placement procedure (range: 2-7 procedures). The mean forced expiratory volume in one second (FEV(1) ), forced expiratory flow rate in the midportion of the forced vital capacity curve (FEF(25-75) ), forced vital capacity, and peak flow (PF) rate obtained before stent placement were compared with those immediately after stent placement and with those measurements most remote from stent placement using the paired two-tailed test.
RESULTS: All patients reported improved respiratory function immediately after stent placement. The mean FEV(1), FEF(25-75), and PF rate improved significantly (p < 0.001, p = 0.002, and p = 0.009, respectively) after stent placement. On long-term follow-up averaging 15 months after stent placement, these parameters declined despite patients' subjective sense of improvement. Segregating the population into transplant and nontransplant airway stenosis etiologies, however, FEF(25-75) and PF rate remained significantly improved (p = 0.045, p = 0.027, respectively), over the long term for the latter. FEV increased after subsequent stent placements for patients receiving multiple stents.
CONCLUSION: Stent placement for benign tracheobronchial stenoses provides significant immediate improvement in airflow dynamics. Long-term improvement in airflow obstruction may be expected, and additional stent placements may further improve pulmonary function.

Entities:  

Mesh:

Year:  2002        PMID: 12218821     DOI: 10.1097/00004728-200207000-00016

Source DB:  PubMed          Journal:  J Comput Assist Tomogr        ISSN: 0363-8715            Impact factor:   1.826


  7 in total

Review 1.  Pharmacological therapy for Wegener's granulomatosis.

Authors:  Eric S White; Joseph P Lynch
Journal:  Drugs       Date:  2006       Impact factor: 9.546

2.  Metallic stent insertion and removal for post-tracheotomy and post-intubation tracheal stenosis.

Authors:  Yonghua Bi; Zepeng Yu; Jianzhuang Ren; Xinwei Han; Gang Wu
Journal:  Radiol Med       Date:  2018-10-24       Impact factor: 3.469

3.  Airway stent complications: the role of follow-up bronchoscopy as a surveillance method.

Authors:  Hans J Lee; Wassim Labaki; Diana H Yu; Benjamin Salwen; Christopher Gilbert; Andrea L C Schneider; Ricardo Ortiz; David Feller-Kopman; Sixto Arias; Lonny Yarmus
Journal:  J Thorac Dis       Date:  2017-11       Impact factor: 2.895

4.  Broncho-vascular fistulas from self-expanding metallic stents: A retrospective case review.

Authors:  Chirag Choudhary; Debabrata Bandyopadhyay; Reyadh Salman; Thomas Gildea; Atul Mehta
Journal:  Ann Thorac Med       Date:  2013-04       Impact factor: 2.219

5.  Protective effects of Korean red ginseng against radiation-induced apoptosis in human HaCaT keratinocytes.

Authors:  Jae Won Chang; Keun Hyung Park; Hye Sook Hwang; Yoo Seob Shin; Young-Taek Oh; Chul-Ho Kim
Journal:  J Radiat Res       Date:  2013-09-26       Impact factor: 2.724

6.  Clinical outcomes of metallic Y-shaped covered stents for bronchopleural fistula around upper carina after lobectomy.

Authors:  Yonghua Bi; Xiaoyan Zhu; Zepeng Yu; Gang Wu; Xinwei Han; Jianzhuang Ren
Journal:  BMC Pulm Med       Date:  2019-11-05       Impact factor: 3.317

7.  Numerical analysis of airflow alteration in central airways following tracheobronchial stent placement.

Authors:  Chien-Yi Ho; Hsiu-Mei Liao; Chih-Yen Tu; Chih-Yang Huang; Chuen-Ming Shih; Min-Ying Lydia Su; Jeon-Hor Chen; Tzu-Ching Shih
Journal:  Exp Hematol Oncol       Date:  2012-08-27
  7 in total

北京卡尤迪生物科技股份有限公司 © 2022-2023.