Narrowband auscultatory blood pressure measurement.

Daniel J Sebald1, Dennis E Bahr, Alan R Kahn.   

Abstract

Auscultatory blood pressure measurement uses the presence and absence of acoustic pulses generated by an artery (i.e., Korotkoff sound), detected with a stethoscope or a sensitive microphone, to noninvasively estimate systolic and diastolic pressures. Unfortunately, in high noise situations, such as ambulatory environments or when the patient moves moderately, the current auscultatory blood pressure method is unreliable, if at all possible. Empirical evidence suggests that the pulse beneath an artery occlusion travels relatively slow compared with the speed of sound. By placing two microphones along the bicep muscle near the brachial artery under the occlusion cuff, a similar blood pressure pulse appears in the two microphones with a relative time delay. The acoustic noise, on the other hand, appears in both microphones simultaneously. The contribution of this paper is to utilize this phenomenon by filtering the microphone waveforms to create spatially narrowband information signals. With a narrowband signal, the microphone signal phasing information is adequate for distinguishing between acoustic noise and the blood pressure pulse. By choosing the microphone spacing correctly, subtraction of the two signals will enhance the information signal and cancel the noise signal. The general spacing problem is also presented.

Entities:  

Mesh:

Year:  2002        PMID: 12214876     DOI: 10.1109/TBME.2002.802056

Source DB:  PubMed          Journal:  IEEE Trans Biomed Eng        ISSN: 0018-9294            Impact factor:   4.538


  3 in total

1.  The impact of arm position and pulse pressure on the validation of a wrist-cuff blood pressure measurement device in a high risk population.

Authors:  Ali Reza Khoshdel; Shane Carney; Alastair Gillies
Journal:  Int J Gen Med       Date:  2010-04-08

2.  Deep learning-based robust automatic non-invasive measurement of blood pressure using Korotkoff sounds.

Authors:  Ji-Ho Chang; Il Doh
Journal:  Sci Rep       Date:  2021-12-03       Impact factor: 4.379

3.  Comparison of systolic blood pressure values obtained by photoplethysmography and by Korotkoff sounds.

Authors:  Meir Nitzan; Yair Adar; Ellie Hoffman; Eran Shalom; Shlomo Engelberg; Iddo Z Ben-Dov; Michael Bursztyn
Journal:  Sensors (Basel)       Date:  2013-10-31       Impact factor: 3.576

  3 in total

北京卡尤迪生物科技股份有限公司 © 2022-2023.