Abstract
We present an unusual complication caused by a dialysis catheter inserted through the internal jugular vein into the central venous system. The 49-year-old male patient developed a right atrial thrombus, which became infected with Staphylococcus aureus, resulting in septic pulmonary embolism and septicemic shock. The thrombus was excised on cardiopulmonary bypass. The patient made an uneventful recovery.Entities:
Mesh:
Year: 2002 PMID: 12213751 DOI: 10.1177/021849230201000314
Source DB: PubMed Journal: Asian Cardiovasc Thorac Ann ISSN: 0218-4923