Literature DB >> 12210504

On-Line HPLC-UV-mass spectrometry and tandem mass spectrometry for the rapid delineation and characterization of differences in complex mixtures: a case study using toxic oil variants.

Frank W Crow1, Jennifer D Cragun, Kenneth L Johnson, Maria Victoria Ruiz, Manuel Posada De La Paz, Stephen Naylor.   

Abstract

An integrated differential approach to the characterization of complex mixtures is presented which includes the targeting of liquid chromatography (LC) peaks for identification using characteristic UV adsorption of the LC peak, subsequent molecular weight and formula determination using accurate mass LC mass spectrometry (MS), and structure characterization using accurate mass LC-tandem mass spectrometry. The use of differential UV adsorption aids in narrowing the scope of the study to only specific peaks of interest. Accurate mass measurement of the molecular ion species provides molecular weight information as well as atomic composition information. The tandem MS (MS/MS) spectra provide fragmentation information which allows for structural characterization of each component. Accurate mass assignment of each of the fragment ions in the MS/MS spectrum provides atomic composition for each of the fragment ions and thus further aids in the structural characterization. These experiments are facilitated through the use of on-line LC-MS and LC-MS/MS with in-line UV detection. A synthetic toxic oil (STO) related to Toxic Oil Syndrome is studied with a focus on possible contaminants resulting from the interaction of aniline, used as a denaturant, with the normal components of the oil. A differential analysis between the STO and a control oil is performed. LC peaks were targeted using UV absorbance to indicate the possible presence of the aniline moiety. Further differential analysis was performed through the determination of the MS signals associated with each component separated on the LC. Finally, the MS/MS data was also used to determine if the fragmentation of the targeted components indicated the presence of aniline. The MS/MS and accurate mass data were used to assign the structures for the targeted components. Copyright 2002 John Wiley & Sons, Ltd.

Entities:  

Mesh:

Substances:

Year:  2002        PMID: 12210504     DOI: 10.1002/bmc.160

Source DB:  PubMed          Journal:  Biomed Chromatogr        ISSN: 0269-3879            Impact factor:   1.902


  2 in total

1.  Tandem laser-induced fluorescence and mass spectrometry detection for high-performance liquid chromatography analysis of the in vitro metabolism of doxorubicin.

Authors:  Joseph B Katzenmeyer; Christopher V Eddy; Edgar A Arriaga
Journal:  Anal Chem       Date:  2010-10-01       Impact factor: 6.986

2.  Detection and characterization by mass spectrometry of radical adducts produced by linoleic acid oxidation.

Authors:  Ana Reis; M Rosário M Domingues; Francisco M L Amado; A J V Ferrer-Correia; Pedro Domingues
Journal:  J Am Soc Mass Spectrom       Date:  2003-11       Impact factor: 3.109

  2 in total

北京卡尤迪生物科技股份有限公司 © 2022-2023.